| Literature DB >> 31271013 |
Lili Wei1, Xia Xue1, Yanming Liu1, Lizhen Sun1, Zhi Cheng1, Shufang Su1, Yin Zhao1.
Abstract
An analytical method was developed for the determination of streptomycin and dihydrostreptomycin in honey using hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). The streptomycin and dihydrostreptomycin residues in the test samples were extracted with 20 g/L trichloroacetic acid aqueous solution (including 50 mmol/L phosphate, pH 6.8) and cleaned on an Oasis HLB solid phase extraction column. The products were separated on a SIELC Obelisc R column with gradient elution using 0.5% (v/v) formic acid aqueous solution and acetonitrile as mobile phases. Streptomycin and dihydrostreptomycin were detected by liquid chromatography-tandem mass spectrometry in the positive ion mode using the external standard method. Under the optimal conditions, streptomycin and dihydrostreptomycin showed good linearity (r>0.99) in the range of 2.5-100 μg/L. The LOD and LOQ of the method was 2.0 μg/kg and 5.0 μg/kg, respectively. The spiked recoveries of the analytes from blank honey samples at the three levels of 5.0, 20.0 and 100.0 μg/kg were in the range of 86.9%-113.2% with the relative standard deviations less than 10%. With the advantages of convenience, rapidity, sensitivity and good repeatability, the method is suitable for the detection of streptomycin and dihydrostreptomycin in honey.Entities:
Keywords: dihydrostreptomycin (DHSTR); honey; hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS); solid phase extraction (SPE); streptomycin (STR)
Mesh:
Substances:
Year: 2019 PMID: 31271013 DOI: 10.3724/SP.J.1123.2019.01029
Source DB: PubMed Journal: Se Pu ISSN: 1000-8713