| Literature DB >> 31260970 |
J R Bertolín1, M Joy2, M Blanco3.
Abstract
The objective of this study was to develop an accurate and fast method to determine malondialdehyde (MDA) levels in raw and processed meat. This method is based on extraction with trichloroacetic acid (TCA), reaction with 2-thiobarbituric acid (TBA) and quantification with ultraperformance liquid chromatography with a fluorescence detector (UPLC-FLD) with ʎexcitation = 530 nm and ʎemission = 550 nm and with a diode array detector (UPLC-DAD) with ʎabsorbance = 532 nm. The method tested was compared with the TBARS spectrophotometric method with ʎabsorbance = 532 nm. The concentration of MDA was similar for most of the matrices in both UPLC methods, except for cooked ham and frankfurter sausage. The TBARS spectrophotometric method overestimated the MDA concentration in all the matrices. Therefore, the use of both chromatographic methods, especially UPLC-FLD, to determine MDA would be more advisable than the classic TBARS method to avoid overestimation in meat and processed meat products.Entities:
Keywords: 2-Thiobarbituric acid derivatization; Absorbance; Fluorescence; Lipid oxidation; TBARS
Mesh:
Substances:
Year: 2019 PMID: 31260970 DOI: 10.1016/j.foodchem.2019.125009
Source DB: PubMed Journal: Food Chem ISSN: 0308-8146 Impact factor: 7.514