Literature DB >> 31260906

Designing and fabrication of new VIP biosensor for the rapid and selective detection of foot-and-mouth disease virus (FMDV).

Heba A Hussein1, Rabeay Y A Hassan2, Rasha Mohamed El Nashar3, Samy A Khalil4, Sayed A Salem5, Ibrahim M El-Sherbiny6.   

Abstract

Foot and mouth disease virus (FMDV), is a highly contagious virus due to its ease of transmission. FMDV has seven genetically distinguished serotypes with many subtypes within each serotype. The traditional diagnostic methods of FMDV have demonstrated many drawbacks related to sensitivity, specificity, and cross-reactivity. In the current study, a new viral imprinted polymer (VIP)-based biosensor was designed and fabricated for the rapid and selective detection of the FMDV. The bio-recognition components were formed via electrochemical polymerization of the oxidized O-aminophenol (O-AP) film imprinted with FMDV serotype O on a gold screen-printed electrode (SPE). The overall changes in the design template have been investigated using cyclic voltammetry (CV), atomic force microscopy (AFM), Field emission-scanning electron microscopy (FE-SEM), and Fourier-transform infrared spectroscopy (FT-IR). Optimal conditions were achieved through investigating the capturing efficiency, binding stability, selectivity and life-time of the developed biosensor. The results depicted a high selectivity of the biosensor to the serotype O over all other genus serotypes A, SAT2 and Lumpy skin disease virus (LSDV), as well as, the inactivated serotype O. The limits of detection (LOD) and quantification (LOQ) were around 2 ng/mL and 6 ng/mL, respectively, in addition to the tested repeatability and reproducibility values with a variance coefficient of 1.0% and 3.6%, respectively. In comparison with the reference methods (ELISA and PCR), the analysis of saliva real samples using the developed affordable biosensor offered 50 folds lower LOD with the possibility of an on-line monitoring in the field with no prior sample treatment.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biomimetic virus biosensors; Foot and mouth disease virus (FMDV); Screen printed electrode (SPE); Virus imprinted polymers (VIPs)

Year:  2019        PMID: 31260906     DOI: 10.1016/j.bios.2019.111467

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Properties and Applications of Graphene and Its Derivatives in Biosensors for Cancer Detection: A Comprehensive Review.

Authors:  Mehrab Pourmadadi; Homayoon Soleimani Dinani; Fatemeh Saeidi Tabar; Kajal Khassi; Sajjad Janfaza; Nishat Tasnim; Mina Hoorfar
Journal:  Biosensors (Basel)       Date:  2022-04-24

Review 2.  Pathogen detection with electrochemical biosensors: Advantages, challenges and future perspectives.

Authors:  Hüseyin Oğuzhan Kaya; Arif E Cetin; Mostafa Azimzadeh; Seda Nur Topkaya
Journal:  J Electroanal Chem (Lausanne)       Date:  2021-01-09       Impact factor: 4.464

3.  Voltammetric determination of Salmonella typhimurium in minced beef meat using a chip-based imprinted sensor.

Authors:  Shaimaa A Khalid; Rabeay Y A Hassan; Rasha Mohamed El Nashar; Ibrahim M El-Sherbiny
Journal:  RSC Adv       Date:  2022-01-25       Impact factor: 3.361

Review 4.  Advances in Electrochemical Nano-Biosensors for Biomedical and Environmental Applications: From Current Work to Future Perspectives.

Authors:  Rabeay Y A Hassan
Journal:  Sensors (Basel)       Date:  2022-10-05       Impact factor: 3.847

Review 5.  Point-of-Care Diagnostics of COVID-19: From Current Work to Future Perspectives.

Authors:  Heba A Hussein; Rabeay Y A Hassan; Marco Chino; Ferdinando Febbraio
Journal:  Sensors (Basel)       Date:  2020-07-31       Impact factor: 3.576

Review 6.  An Overview of Bio-Inspired Intelligent Imprinted Polymers for Virus Determination.

Authors:  Shabi Abbas Zaidi
Journal:  Biosensors (Basel)       Date:  2021-03-21
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.