Literature DB >> 31257052

Torsion and linear accuracy in intraoral scans obtained with different scanning principles.

Alexander Schmidt1, Christopher R Benedickt2, Maximiliane A Schlenz3, Peter Rehmann3, Bernd Wöstmann3.   

Abstract

PURPOSE: Few investigations have examined the production of single restorations using intraoral scanners (IOS). Data on full-arch scans are rare, and data regarding torsion within the entire arch are very sparsely reported. Therefore, the aim of this study was to examine the deviations of torsion and linear distances in full-arch scans of three IOS based on different scanning principles.
METHODS: A cobalt-chrome-molybdenum alloy master model (CCMM) with four hemispheres was fabricated by laser sintering. The CCMM was digitized using a laboratory scanner (ATOS-Core/GOM) and scanned with three IOS (Omnicam/Sirona(OC); True Definition/3M(TD); TriosII/Cara-Version/Kulzer(TR)). All scan data were exported in a standard STL-file format and were analyzed with GOM Inspect software (V7.5/GOM). Torsion between the right and left side of the arch and linear accuracy (trueness and precision) were evaluated. After normality was confirmed, all data were subjected to parametric statistical analyses.
RESULTS: The torsion ranged from 0.07±0.03°(OC) to 0.29±0.14°(TD). Pairwise comparisons showed significant differences between the OC and TD scanners and between the TR and TD scanners. The linear distances ranged from 6±5μm(OC) to 298±317μm(TD). Significant differences were observed among all investigated IOS (p=0.05).
CONCLUSIONS: Although the highest torsion was observed for the TD scanner, it is still not clear whether the differences between the IOS are related to the scanning principle or to the scanning algorithm. Due to the high clinical relevance of full-arch restorations, future studies should consider torsion. Regarding linear accuracy, no general difference related to the scanning principles of the IOSs was observed.
Copyright © 2019 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Keywords:  Intraoral scanning accuracy; Intraoral scanning torsion; Trueness and precision

Year:  2019        PMID: 31257052     DOI: 10.1016/j.jpor.2019.06.006

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  3 in total

1.  Accuracy of full-arch digitalization for partially edentulous jaws - a laboratory study on basis of coordinate-based data analysis.

Authors:  Panagiotis Kontis; Jan-Frederik Güth; Christine Keul
Journal:  Clin Oral Investig       Date:  2022-01-04       Impact factor: 3.573

2.  Update on the Accuracy of Conventional and Digital Full-Arch Impressions of Partially Edentulous and Fully Dentate Jaws in Young and Elderly Subjects: A Clinical Trial.

Authors:  Maximiliane Amelie Schlenz; Julian Maximilian Stillersfeld; Bernd Wöstmann; Alexander Schmidt
Journal:  J Clin Med       Date:  2022-06-28       Impact factor: 4.964

3.  Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update.

Authors:  Alexander Schmidt; Leona Klussmann; Bernd Wöstmann; Maximiliane Amelie Schlenz
Journal:  J Clin Med       Date:  2020-03-04       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.