Literature DB >> 31256674

Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis.

V P Galea1, P Rojanasopondist1, M Laursen2, O K Muratoglu1,3, H Malchau1,3, C Bragdon1,3.   

Abstract

AIMS: Vitamin E-diffused, highly crosslinked polyethylene (VEPE) and porous titanium-coated (PTC) shells were introduced in total hip arthroplasty (THA) to reduce the risk of aseptic loosening. The purpose of this study was: 1) to compare the wear properties of VEPE to moderately crosslinked polyethylene; 2) to assess the stability of PTC shells; and 3) to report their clinical outcomes at seven years. PATIENTS AND METHODS: A total of 89 patients were enrolled into a prospective study. All patients received a PTC shell and were randomized to receive a VEPE liner (n = 44) or a moderately crosslinked polyethylene (ModXLPE) liner (n = 45). Radiostereometric analysis (RSA) was used to measure polyethylene wear and component migration. Differences in wear were assessed while adjusting for body mass index, activity level, acetabular inclination, anteversion, and head size. Plain radiographs were assessed for radiolucency and patient-reported outcome measures (PROMs) were administered at each follow-up.
RESULTS: In total, 73 patients (82%) completed the seven-year visit. Mean seven-year linear proximal penetration was -0.07 mm (sd 0.16) and 0.00 mm (sd 0.22) for the VEPE and ModXLPE cohorts, respectively (p = 0.116). PROMs (p = 0.310 to 0.807) and radiolucency incidence (p = 0.330) were not different between the polyethylene cohorts. The mean proximal shell migration rate was 0.04 mm per year (sd 0.09). At seven years, patients with radiolucency (34%) demonstrated greater migration (mean difference: 0.6 mm (sd 0.2); p < 0.001). PROMs were lower for patients with radiolucency and greater proximal migration (p = 0.009 to p = 0.045). No implants were revised for aseptic loosening.
CONCLUSION: This is the first randomized controlled trial to report seven-year RSA results for VEPE. All wear rates were below the previously reported osteolysis threshold (0.1 mm per year). PTC shells demonstrated acceptable primary stability through seven years, as indicated by low migration and lack of aseptic loosening. However, patients with acetabular radiolucency were associated with higher shell migration and lower PROM scores. Cite this article: Bone Joint J 2019;101-B:760-767.

Entities:  

Keywords:  Moderately crosslinked polyethylene; Radiostereometric analysis; Total hip arthroplasty; Vitamin-E polyethylene

Mesh:

Substances:

Year:  2019        PMID: 31256674     DOI: 10.1302/0301-620X.101B7.BJJ-2019-0268.R1

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  8 in total

1.  Minimum ten-year follow-up of a randomized trial comparing acetabular component fixation of two porous in-growth surfaces using radiosteriometric analysis.

Authors:  Luthfur Rahman; Mazin S Ibrahim; Lyndsay Somerville; Matthew G Teeter; Douglas D Naudie; Richard W McCalden
Journal:  Bone Jt Open       Date:  2020-10-20

2.  A higher degree of polyethylene irradiation is associated with a reduced risk of revision for aseptic loosening in total hip arthroplasties using cemented acetabular components: an analysis of 290,770 cases from the National Joint Registry of England, Wales, Northern Island and the Isle of Man.

Authors:  Edward T Davis; Joseph Pagkalos; Branko Kopjar
Journal:  Bone Joint Res       Date:  2020-09-20       Impact factor: 5.853

3.  Implant survival of 2,723 vitamin E-infused highly crosslinked polyethylene liners in total hip arthroplasty: data from the Finnish Arthroplasty Register.

Authors:  Matias Hemmilä; Inari Laaksonen; Markus Matilainen; Antti Eskelinen; Jaason Haapakoski; Ari-Pekka Puhto; Jukka Kettunen; Konsta Pamilo; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2021-02-01       Impact factor: 3.717

4.  Vitamin E-Enhanced Liners in Primary Total Hip Arthroplasty: A Systematic Review and Meta-Analysis.

Authors:  Qian-Yue Cheng; Bin-Fei Zhang; Peng-Fei Wen; Jun Wang; Lin-Jie Hao; Tao Wang; Hui-Guang Cheng; Ya-Kang Wang; Jian-Bin Guo; Yu-Min Zhang
Journal:  Biomed Res Int       Date:  2021-12-06       Impact factor: 3.411

5.  Roentgen stereophotogrammetric analysis: still a very valuable tool in the orthopaedic research armamentarium.

Authors:  Andreas Fontalis; Fares S Haddad
Journal:  Bone Joint Res       Date:  2022-04       Impact factor: 4.410

6.  Vitamin E-doped total hip arthroplasty liners show similar head penetration to highly cross-linked polyethylene at five years: a multi-arm randomized controlled trial.

Authors:  Kristian Kjærgaard; Ming Ding; Carsten Jensen; Charles Bragdon; Henrik Malchau; Christina M Andreasen; Ole Ovesen; Christian Hofbauer; Søren Overgaard
Journal:  Bone Joint J       Date:  2020-10       Impact factor: 5.082

7.  Vitamin E infused highly cross-linked cemented cups in total hip arthroplasty show good wear pattern and stabilize satisfactorily: a randomized, controlled RSA trial with 5-year follow-up.

Authors:  Halldor Bergvinsson; Vasilis Zampelis; Martin Sundberg; Jon Tjörnstrand; Gunnar Flivik
Journal:  Acta Orthop       Date:  2022-01-20       Impact factor: 3.717

8.  Identification of Key Candidate Genes Related to Inflammatory Osteolysis Associated with Vitamin E-Blended UHMWPE Debris of Orthopedic Implants by Integrated Bioinformatics Analysis and Experimental Confirmation.

Authors:  Fanxiao Liu; Jun Dong; Dongsheng Zhou; Qingyu Zhang
Journal:  J Inflamm Res       Date:  2021-07-26
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.