Literature DB >> 31256583

Novel 3D Printed Device for Dual-Signaling Ratiometric Photoelectrochemical Readout of Biomarker Using λ-Exonuclease-Assisted Recycling Amplification.

Kangyao Zhang1, Shuzhen Lv1, Dianping Tang1.   

Abstract

A ratiometric photoelectrochemical (PEC) sensing strategy was proposed for monitoring of carcinoembryonic antigen (CEA) based on a homemade 3D printing device with dual-working photoelectrodes (PE1 and PE2), coupling λ-exonuclease (λ-Exo)-assisted recycling amplification with CdS quantum dots. Gold nanoparticles-functionalized ZnO nanorods were utilized as PEC substrate for generating initial photocurrent and immobilizing DNA probe. Upon incubation of target with DNA trigger/CEA aptamer-modified magnetic bead (tri/apt-MB), DNA trigger dissociated from magnetic bead and then hybridized with capture probe (cp) on PE1 or opened hairpin probe (hp) on PE2 to form double-stranded DNA (dsDNA). The exonuclease could recognize and cleave two newly generated dsDNA, leading to the release of trigger. The free trigger strand continued to hybridize with the remaining cp/hp, which were cleaved by λ-Exo, and then trigger was released again and restarted next recycle with the λ-Exo. After digestion of λ-Exo, the number of capture probes on PE1 was reduced, and many short DNA fragments were produced on PE2, thereby resulting in the decreasing CdS QDs on PE1 and the increasing CdS QDs on PE2. As a result, it was observed that the ratio value of photocurrents (PE1/PE2) significantly decreased with the increasing CEA. Under optimum conditions, the sensing method showed a good linear relationship toward CEA within the dynamic range of 0.02-10 ng mL-1 and a detection limit of 6.0 pg mL-1. Moreover, the ratiometric PEC sensor exhibited good reproducibility, satisfying stability, and remarkable anti-interference performance, which suggests its promising application prospect to detect target CEA.

Entities:  

Year:  2019        PMID: 31256583     DOI: 10.1021/acs.analchem.9b01958

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  Accurate identification of kidney injury progression via a fluorescent biosensor array.

Authors:  Xie-An Yu; Lei Zhang; Ran Zhang; Xuefei Bai; Ying Zhang; Yiting Hu; Yang Wu; Ziyi Li; Bing Wang; Jiangwei Tian
Journal:  Mikrochim Acta       Date:  2022-08-01       Impact factor: 6.408

2.  Biosensor Based on Covalent Organic Framework Immobilized Acetylcholinesterase for Ratiometric Detection of Carbaryl.

Authors:  Ying Luo; Na Wu; Linyu Wang; Yonghai Song; Yan Du; Guangran Ma
Journal:  Biosensors (Basel)       Date:  2022-08-10

Review 3.  3D-Printed Immunosensor Arrays for Cancer Diagnostics.

Authors:  Mohamed Sharafeldin; Karteek Kadimisetty; Ketki S Bhalerao; Tianqi Chen; James F Rusling
Journal:  Sensors (Basel)       Date:  2020-08-12       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.