Literature DB >> 31255546

Influence of implant scanbody material, position and operator on the accuracy of digital impression for complete-arch: A randomized in vitro trial.

Lorenzo Arcuri1, Alessandro Pozzi2, Fabrizio Lio1, Eric Rompen3, Werner Zechner4, Alessandra Nardi5.   

Abstract

PURPOSE: To evaluate the influence of implant scanbody (ISB) material, position and operator on the accuracy of a confocal microscopy intraoral scanning (IOS) for complete-arch implant impression.
METHODS: An edentulous maxillary model with 6 internal hexagonal connection analogues was scanned with an extraoral optical scanner to achieve a reference file. Three ISBs made of different materials (polyetheretherketone (Pk), titanium (T) and Pk with a titanium base (Pkt)) were scanned with IOS by 3 operators. The resulting 45 test files were aligned to the reference file with a best fit algorithm. Linear (ΔX, ΔY and ΔZ-axis) and angular deviations (ΔANGLE) were assessed. Absolute values of the linear discrepancies were summed up to obtain a global measure of linear absolute error (ΔASS). Influence of ISB material, position and operator was statistically assessed using the mixed general linear model.
RESULTS: At multivariate analysis, whenΔASS was considered as response variable, it was identified a significant influence of material (p<0.0001) and position (p=0.0009) while no significant operator effect was detected. When ΔANGLE was considered as response variable, material and position significantly influenced the expected ΔANGLE (p=0.0232 and p<0.0001) and no operator effect was identified.
CONCLUSIONS: The investigated IOS for complete-arch digital impression was influenced by the ISB material with peek reporting the best results on both linear and angular measurements followed by titanium, peek-titanium resulting as the less accurate. Implant angulation affected significantly the linear deviations while implant position the angular deviations. Operator did not show any significant effect on the IOS accuracy.
Copyright © 2019 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Complete-arch; Digital impression; Implant scanbody; Ios; Peek

Mesh:

Substances:

Year:  2019        PMID: 31255546     DOI: 10.1016/j.jpor.2019.06.001

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  16 in total

1.  A new 3D-method to assess the inter implant dimensions in patients - A pilot study.

Authors:  Alexander Schmidt; Jan-Wilhelm Billig; Maximiliane A Schlenz; Bernd Wöstmann
Journal:  J Clin Exp Dent       Date:  2020-02-01

Review 2.  Review on Development and Dental Applications of Polyetheretherketone-Based Biomaterials and Restorations.

Authors:  Ludan Qin; Shuo Yao; Jiaxin Zhao; Chuanjian Zhou; Thomas W Oates; Michael D Weir; Junling Wu; Hockin H K Xu
Journal:  Materials (Basel)       Date:  2021-01-15       Impact factor: 3.623

Review 3.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

Review 4.  Digital Impressions in Implant Dentistry: A Literature Review.

Authors:  Simone Marques; Paulo Ribeiro; Carlos Falcão; Bernardo Ferreira Lemos; Blanca Ríos-Carrasco; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2021-01-24       Impact factor: 3.390

5.  Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study.

Authors:  Bowen Ma; Xinxin Yue; Yujie Sun; Lingyan Peng; Wei Geng
Journal:  BMC Oral Health       Date:  2021-12-10       Impact factor: 2.757

Review 6.  Trueness and precision of digital implant impressions by intraoral scanners: a literature review.

Authors:  Minoru Sanda; Keita Miyoshi; Kazuyoshi Baba
Journal:  Int J Implant Dent       Date:  2021-07-27

7.  Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation.

Authors:  Francesco Guido Mangano; Matteo Bonacina; Federico Mandelli; Fabio Marchiori
Journal:  BMC Res Notes       Date:  2020-11-03

8.  Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study.

Authors:  Francesco Guido Mangano; Oleg Admakin; Matteo Bonacina; Henriette Lerner; Vygandas Rutkunas; Carlo Mangano
Journal:  BMC Oral Health       Date:  2020-09-22       Impact factor: 2.757

9.  Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation.

Authors:  Jaafar Abduo; Joseph E A Palamara
Journal:  Int J Implant Dent       Date:  2021-07-30

10.  Improved accuracy of digital implant impressions with newly designed scan bodies: an in vivo evaluation in beagle dogs.

Authors:  Ruoxuan Huang; Yuanxiang Liu; Baoxin Huang; Fengxing Zhou; Zhuofan Chen; Zhipeng Li
Journal:  BMC Oral Health       Date:  2021-12-07       Impact factor: 2.757