Literature DB >> 31254031

Customised bi-compartmental knee arthroplasty shows encouraging 3-year results: findings of a prospective, multicenter study.

J Beckmann1, A F Steinert2, B Huber3, M Rudert2, F X Köck4, M Buhs5, L Rolston6.   

Abstract

PURPOSE: The purpose of this study was to assess the clinical and patient-reported outcomes of a customised, individually made (CIM) bi-compartmental knee arthroplasty (BKA).
METHODS: A prospectively recruited cohort of 79 patients was implanted with a CIM-BKA (patello-femoral plus either medial or lateral tibio-femoral, iDuo G2 system, Conformis, Billerica MA) at eight centres in the US and Germany. Patients were assessed for the 2011 KSS, KOOS, and ROM pre-operatively and at 2 weeks, 6 weeks, 12 weeks, 1 year, and 2 years post-operatively.
RESULTS: The objective KSS score significantly improved from 69 at the pre-operative visit, to 94 at the 2-year post-operative time-point. Similar improvements were observed for the KSS function and satisfaction domains. Significant improvements from pre-operative levels were observed across all five domains of the KOOS. Two patients have undergone surgery to revise their CIM-BKA implant to total knees, resulting in a survivorship rate of 97.5% at an average follow-up of 2.6 years.
CONCLUSIONS: CIM-BKA compares favourably to published scores as well as revision rates for previously available monolithic OTS-BKA implants. CIM-BKA implants provide surgeons with a viable and patient-specific monolithic implant solution as an option for patients presenting with bi-compartmental disease, who might, otherwise, be treated by performing uni-condylar + patello-femoral joint or bicruciate sparing TKA surgeries. Longer follow-up and higher numbers have to be awaited for further validation of these encouraging early results. LEVEL OF EVIDENCE: 3b (individual case-controlled study).

Entities:  

Keywords:  BKR; Bi-compartment; Bicruciate retaining; Customised; Individualised; Total knee replacement

Year:  2019        PMID: 31254031     DOI: 10.1007/s00167-019-05595-z

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  5 in total

Review 1.  [New technologies (robotics, custom-made) in unicondylar knee arthroplasty-pro].

Authors:  Malin Meier; Tilman Calliess; Carsten Tibesku; Johannes Beckmann
Journal:  Orthopade       Date:  2021-02       Impact factor: 1.087

2.  Relevant changes of leg alignment after customised individually made bicompartmental knee arthroplasty due to overstuffing.

Authors:  Sonia Shamdasani; Nicole Vogel; Raphael Kaelin; Achim Kaim; Markus P Arnold
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-09-11       Impact factor: 4.114

Review 3.  Biomechanical and Clinical Effect of Patient-Specific or Customized Knee Implants: A Review.

Authors:  Jin-Ah Lee; Yong-Gon Koh; Kyoung-Tak Kang
Journal:  J Clin Med       Date:  2020-05-21       Impact factor: 4.241

4.  The Impact of Total Knee Replacement with a Customized Cruciate-Retaining Implant Design on Patient-Reported and Functional Outcomes.

Authors:  Andre F Steinert; Lennart Schröder; Lukas Sefrin; Björn Janßen; Jörg Arnholdt; Maximilian Rudert
Journal:  J Pers Med       Date:  2022-01-31

Review 5.  Contemporary knee arthroplasty: one fits all or time for diversity?

Authors:  Johannes Beckmann; Malin Kristin Meier; Christian Benignus; Andreas Hecker; Emmanuel Thienpont
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-16       Impact factor: 3.067

  5 in total