Literature DB >> 31253505

Long-term mass flux assessment of a DNAPL source area treated using bioremediation.

Alexander A Haluska1, Charles E Schaefer2, Jaehyun Cho3, Graig M Lavorgna4, Michael D Annable3.   

Abstract

This study assessed the long-term effectiveness of bioremediation as a remedial strategy for a chlorinated, ethene dense, non-aqueous phase liquid (DNAPL) source area, consisting of a higher- and a lower-permeability zone at Alameda Point, California. The evaluation was performed over 3.7 years after cessation of active source area bioremediation using passive flux meters (PFMs), push-pull tracer tests, and soil cores. PFMs showed that total chlorinated ethene molar discharge emanating from the source area remained relatively unchanged pre-and post-bioremediation, but molar discharge compositions shifted from trichloroethene (TCE) and cis-1,2-dichloroethene (cis-DCE) to vinyl chloride (VC) and ethene dominated during post-remedial monitoring. First-order rate constants, derived from PFM data at the edge of the source area and describing the complete dechlorination of TCE at 3.7 years following active bioremediation, were approximately 1.05 yr-1, which was over three times lower than the rate 3.6 yr-1 determined using compound stable isotope analysis (CSIA). Soil cores and push-pull tracer test data showed that DNAPL volume estimates were relatively unchanged pre- and post-bioremediation due to the remaining presence of DNAPL in the lower-permeability zone. These data suggest biotransformation processes are continuing in the higher-permeability zone, whereas DNAPL in the lower-permeability zone continues to serve as a significant source of groundwater contamination. The results suggest that it will take many years under current conditions to attain the United States Environmental Protection Agency (EPA) Maximum Contaminant Levels (MCLs) cleanup objectives.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bioremediation; DNAPL; Dissolution; Passive flux meter; Source area; TCE

Mesh:

Substances:

Year:  2019        PMID: 31253505     DOI: 10.1016/j.jconhyd.2019.103516

Source DB:  PubMed          Journal:  J Contam Hydrol        ISSN: 0169-7722            Impact factor:   3.188


  1 in total

1.  Decontamination of dense nonaqueous-phase liquids in groundwater using pump-and-treat and in situ chemical oxidation processes: a field test.

Authors:  Tian Xie; Zhi Dang; Jian Zhang; Qian Zhang; Rong-Hai Zhang; Chang-Jun Liao; Gui-Ning Lu
Journal:  RSC Adv       Date:  2021-01-21       Impact factor: 3.361

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.