Accuracy of examination of the long head of the biceps tendon in the clinical setting: A systematic review.

Valérie Bélanger1, Frédérique Dupuis, Jean Leblond, Jean-Sébastien Roy.   

Abstract

OBJECTIVE: To determine the diagnostic validity of high-resolution ultrasound and orthopaedic special tests in diagnosing long head of the biceps tendon pathologies in patients with shoulder pain.
DESIGN: Systematic review with meta-analysis tools. DATA SOURCES: MEDLINE, CINAHL and EMBASE. DATA EXTRACTION: Included studies had to report on the diagnostic validity of orthopaedic special tests or high-resolution ultrasound (HRUS) compared with a reference standard for diagnosing long head of the biceps tendon target conditions (superior labrum anterior and posterior lesions, long head of the biceps tendon tendinopathy, dislocation, effusion or rupture). Risk of bias was assessed using the Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2) tool.
RESULTS: Of the 30 included studies, 8 focused on high-resolution ultrasound and 22 on orthopaedic special tests. High-resolution ultrasound proved highly specific for the diagnosis of long head of the biceps tendon pathologies. Pooled positive (LR+) and negative (LR-) likelihood ratios were 38.00 and 0.24 for dislocation, respectively, and 35.50 and 0.30 for complete rupture, respectively. The accuracy of orthopaedic special tests varied greatly across studies. The only test of value was Yergason's ma-noeuvre in confirming proximal long head of the biceps tendon pathologies except superior labrum anterior and posterior lesion (high specificity): the summary LR+ and LR- were 2.56 and 0.70, respectively.
CONCLUSION: High-resolution ultrasound is reliable to confirm suspected long head of the biceps tendon pathologies. There is insufficient evidence to recommend individual orthopaedic special tests.

Entities:  

Keywords:  biceps tendon; diagnostic ultrasound; glenoid labrum; imaging; shoulder

Mesh:

Year:  2019        PMID: 31243466     DOI: 10.2340/16501977-2563

Source DB:  PubMed          Journal:  J Rehabil Med        ISSN: 1650-1977            Impact factor:   2.912


  6 in total

1.  Magnetic resonance arthrography is insufficiently accurate to diagnose biceps lesions prior to rotator cuff repair.

Authors:  Elise Loock; Aude Michelet; Amaury D'Utruy; Pierre Molinazzi; Gerjon Hannink; Simon Bertiaux; Olivier Courage
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-07-25       Impact factor: 4.342

2.  The Effectiveness of Ultrasound-Guided Subacromial-Subdeltoid Bursa Combined With Long Head of the Biceps Tendon Sheath Corticosteroid Injection for Hemiplegic Shoulder Pain: A Randomized Controlled Trial.

Authors:  Yajing Hou; Tong Zhang; Wei Liu; Minjie Lu; Yong Wang
Journal:  Front Neurol       Date:  2022-06-14       Impact factor: 4.086

3.  Diagnostic accuracy of magnetic resonance imaging for partial tears of the long head of the biceps tendon in patients with rotator cuff tears.

Authors:  Yuji Shibayama; Toshiaki Hirose; Akira Sugi; Emi Mizushima; Yuto Watanabe; Rira Tomii; Kousuke Iba; Toshihiko Yamashita
Journal:  JSES Int       Date:  2022-04-04

4.  The Prevalence of Shoulder Disorders among Professional Bullfighters: A Cross-Sectional Ultrasonography Study.

Authors:  Álvaro Navas-Mosqueda; Juan Antonio Valera-Calero; Umut Varol; Sebastian Klich; Marcos José Navarro-Santana; César Fernández-de-Las-Peñas; Marta Ríos-León; Pedro Belón-Pérez; Eduardo Cimadevilla-Fernández-Pola; Juan Pablo Hervás-Pérez; José Luis Arias-Buría
Journal:  Tomography       Date:  2022-07-04

5.  Acupuncture for Atraumatic Shoulder Conditions: Protocol for a Systematic Review and Meta-Analysis.

Authors:  Yi Wang; Yan Xu; Yu Peng; Shichuan Liao; Guogang Dai; Tao Li
Journal:  Front Med (Lausanne)       Date:  2022-03-07

Review 6.  What are the patient-reported outcomes, functional limitations, and complications after lesser tuberosity fractures? a systematic review of 172 patients.

Authors:  Reinier W A Spek; Bram J A Schoolmeesters; Chantal den Haan; Ruurd L Jaarsma; Job N Doornberg; Michel P J van den Bekerom
Journal:  JSES Int       Date:  2021-04-20