Literature DB >> 31237120

Transcatheter closure of atrial septal communication: Impact on quality of life in mid-term follow-up.

Maria Lelakowska1, Paweł Tomasz Matusik2, Piotr Stanisław Podolec3, Maria Olszowska3, Jadwiga Maria Nessler1, Natalia Podolec4, Tadeusz Przewłocki3, Monika Komar3.   

Abstract

BACKGROUND: Atrial septal defect (ASD) and patent foramen ovale (PFO) are specific types of atrial septal communications (ASC).
OBJECTIVES: We aimed to assess quality of life (QoL) in patients before and after percutaneous closure of ASC and determine the factors influencing QoL in this group of patients.
MATERIAL AND METHODS: We performed a clinical assessment and conducted an SF-36 questionnaire, electrocardiography and echocardiography studies in patients before and 6 months after percutaneous ASC closure.
RESULTS: Patients with ASD (n = 56) had a lower SF-36 total score than those with PFO (n = 73), before and after percutaneous ASC occlusion (both p < 0.001). After the procedure, the improvement of SF-36 total score in patients with ASD or atrial fibrillation was greater (p < 0.001 and p = 0.005, respectively). We observed correlations between improvement of QoL and baseline supraventricular extrasystolic beats (rs = 0.28; p = 0.002), but not ventricular extrasystolic beats (rs = 0.03; p = 0.76). Quality of life improvement was predicted in patients with ASD by higher baseline tricuspid annular plane systolic excursion (TAPSE) and right ventricular longitudinal dimension R2 = 0.38; p < 0.001. However, in patients with PFO, this was predicted by TAPSE, lack of arterial hypertension and usage of angiotensin-converting enzyme inhibitors, R2 = 0.30; p < 0.001.
CONCLUSIONS: Patients with ASD have lower QoL than those with PFO before and after percutaneous ASC occlusion. Six months after the procedure, the improvement of QoL in patients with ASD was higher than in those with PFO. The change in QoL self-assessed by patients after the procedure was associated with episodes of arrhythmia and was predicted with echocardiographic and clinical parameters.

Entities:  

Keywords:  atrial septal defect; patent foramen ovale; quality of life; transcatheter closure

Mesh:

Year:  2019        PMID: 31237120     DOI: 10.17219/acem/102440

Source DB:  PubMed          Journal:  Adv Clin Exp Med        ISSN: 1899-5276            Impact factor:   1.727


  1 in total

1.  Cost-effectiveness analysis of patent foramen ovale closure versus medical therapy alone after cryptogenic stroke.

Authors:  Yoko Shijoh; Shota Saito; Zhehao Dai; Sachiko Ohde
Journal:  PLoS One       Date:  2022-06-03       Impact factor: 3.752

  1 in total