Abstract

Immunodiagnostic tests performed at the point of care (POC) today usually employ antibodies for biorecognition and are read out either visually or with specialized equipment. Availability of alternative biorecognition elements with promising features as well as smartphone-based approaches for signal readout, however, challenge the described established configuration in terms of analytical performance and practicability. Assessing these developments' clinical relevance and their impact on POC immunodiagnostics is demanding. The first part of this review will therefore give an overview on suitable diagnostic biosensors based on alternative recognition elements (such as nucleic acid-based aptamers or engineered binding proteins) and exemplify advantages and drawbacks of these biomolecules on the base of selected assays. The second part of the review then focuses on smartphone-connected diagnostics and discusses the indispensable considerations required for successful future clinical POCT implementation. Together, the joint depiction of two of the most innovative and exciting developments in the field will enable the reader to cast a glance into the distant future of POC immunodiagnostics.

Entities:  

Keywords:  Biosensor techniques; In vitro diagnostics; Nanomaterials; Near-patient testing; POCT; Point-of-care testing; Recognition elements; Smartphone

Year:  2019        PMID: 31236649     DOI: 10.1007/s00216-019-01974-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Point-of-care-ready nanoscale ISFET arrays for sub-picomolar detection of cytokines in cell cultures.

Authors:  Dipti Rani; Yogesh Singh; Madhuri Salker; Xuan Thang Vu; Sven Ingebrandt; Vivek Pachauri
Journal:  Anal Bioanal Chem       Date:  2020-07-28       Impact factor: 4.142

2.  An integrated device for fast and sensitive immunosuppressant detection.

Authors:  Sara Tombelli; Cosimo Trono; Simone Berneschi; Chiara Berrettoni; Ambra Giannetti; Romeo Bernini; Gianluca Persichetti; Genni Testa; Guillermo Orellana; Francesca Salis; Susanne Weber; Peter B Luppa; Giampiero Porro; Giovanna Quarto; Markus Schubert; Marcel Berner; Paulo P Freitas; Susana Cardoso; Fernando Franco; Vânia Silverio; Maria Lopez-Martinez; Urs Hilbig; Kathrin Freudenberger; Günter Gauglitz; Holger Becker; Claudia Gärtner; Mark T O'Connell; Francesco Baldini
Journal:  Anal Bioanal Chem       Date:  2021-12-22       Impact factor: 4.142

Review 3.  Molecularly Imprinted Polymer-Based Microfluidic Systems for Point-of-Care Applications.

Authors:  Yeşeren Saylan; Adil Denizli
Journal:  Micromachines (Basel)       Date:  2019-11-11       Impact factor: 2.891

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.