Literature DB >> 31235970

Lights-out Surgery for Strabismus Using a Heads-Up 3D Vision System.

Ichiro Hamasaki1, Kiyo Shibata, Takehiro Shimizu, Reika Kono, Yuki Morizane, Fumio Shiraga.   

Abstract

During strabismus surgery using illumination from a light source, patients complain of photophobia. The NGENUITYⓇ (Alcon) system is equipped with a high-dynamic-range (HDR) camera. A 4K display viewed by wearing circularly polarized glasses provides clear three-dimensional images of the operative field. A light source is usually required for surgeries of the anterior segment (including strabismic surgery), but the digital processing function of the NGENUITYⓇ system allows image display in relatively dark regions even without a light source. We devised a novel 'lights-out' surgery that does not use a microscope's light source, and we examined the usefulness of this technique in 2 cases of strabismic surgery. We performed strabismus surgery using the NGENUITYⓇ system in two patients between January and June 2018. The HDR function was used, and the aperture was opened to the maximum while the gain was adjusted. Surgery was conducted without using the microscope's light source. We report the 2 cases' results and evaluate the novel method. The surgeries were performed without problem even though the microscope's light source was not used. The patients' photophobia was alleviated. Lights-out surgery is a potentially useful modality for strabismus surgery.

Entities:  

Keywords:  3D vision system; head-up surgery; high dynamic range; strabismus surgery; video enhancement

Year:  2019        PMID: 31235970     DOI: 10.18926/AMO/56865

Source DB:  PubMed          Journal:  Acta Med Okayama        ISSN: 0386-300X            Impact factor:   0.892


  4 in total

1.  Comparison of Three-Dimensional Surgical System Versus Binocular Microscope for Clear Corneal Incision in Cataract Surgery.

Authors:  Zehui Zhu; Pingjun Chang; Feng Huang; Songqing Shen; Xiaomeng Zhao; Xinpei Ji; Yun E Zhao
Journal:  Ophthalmol Ther       Date:  2022-06-24

2.  External ophthalmic videography - Tools and techniques.

Authors:  Santosh G Honavar
Journal:  Indian J Ophthalmol       Date:  2019-09       Impact factor: 1.848

3.  Use of the heads-up NGENUITY 3D Visualization System for vitreoretinal surgery: a retrospective evaluation of outcomes in a French tertiary center.

Authors:  Pierre Kantor; Frédéric Matonti; Fanny Varenne; Vanessa Sentis; Véronique Pagot-Mathis; Pierre Fournié; Vincent Soler
Journal:  Sci Rep       Date:  2021-05-11       Impact factor: 4.379

4.  Effectiveness of the Heads-Up Surgery System for Retinal Surgery in a Patient with Severe Photophobia.

Authors:  Yuka Saito; Hiroshi Horiguchi; Kei Mizobuchi; Satoshi Katagiri; Hisato Gunji; Tadashi Nakano
Journal:  Int Med Case Rep J       Date:  2021-08-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.