Literature DB >> 31235458

BIOFLOW-IV, a randomised, intercontinental, multicentre study to assess the safety and effectiveness of the Orsiro sirolimus-eluting stent in the treatment of subjects with de novo coronary artery lesions: primary outcome target vessel failure at 12 months.

Shigeru Saito1, Ralph Toelg, Bernhard Witzenbichler, Michael Haude, Monica Masotti, Ruiz Salmeron, Adam Witkowski, Masaaki Uematsu, Akihiko Takahashi, Ron Waksman, Ton Slagboom.   

Abstract

AIMS: The BIOFLOW-IV clinical trial was designed for regulatory submission in Japan. It assessed the safety and efficacy of a new third-generation sirolimus-eluting stent system with bioresorbable polymer (Orsiro, BP-SES) compared with an everolimus-eluting stent system with permanent polymer (XIENCE Prime/Xpedition, PP-EES). METHODS AND
RESULTS: This prospective, international, multicentre, 2:1 randomised, non-inferiority trial enrolled 575 patients (385 BP-SES and 190 PP-EES) with 659 stenotic de novo lesions. Of these, 137 patients (23.8%) were Japanese. Follow-up until five years is ongoing. We herein report outcomes at 12 months. Baseline parameters were well balanced. Device success was 98.9% for BP-SES versus 99.6% for PP-EES, p=0.670. Non-inferiority related to 12-month target vessel failure was met (pnon-inferiority <0.001). Further, there was no significant difference in clinical outcomes between the groups. The target vessel failure rate was 5.5% for BP-SES and 7.5% for PP-EES, the target lesion failure rate was 4.2% versus 5.4%, and the definite or probable stent thrombosis rate was 0.8% versus 0%.
CONCLUSIONS: The randomised BIOFLOW-IV trial provides further evidence on the safety and efficacy of the Orsiro BP-SES and its non-inferiority to the current benchmark, an everolimus-eluting permanent polymer stent. ClinicalTrials.gov: NCT01939249.

Entities:  

Year:  2019        PMID: 31235458     DOI: 10.4244/EIJ-D-18-01214

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  7 in total

1.  Complex vs. non-complex percutaneous coronary intervention with newer-generation drug-eluting stents: an analysis from the randomized BIOFLOW trials.

Authors:  Rayyan Hemetsberger; Mohammad Abdelghani; Ralph Toelg; Hector M Garcia-Garcia; Serdar Farhan; Nader Mankerious; Karim Elbasha; Abdelhakim Allali; Stephan Windecker; Thierry Lefèvre; Shigeru Saito; David Kandzari; Ron Waksman; Gert Richardt
Journal:  Clin Res Cardiol       Date:  2022-02-25       Impact factor: 5.460

2.  Outcomes of patients treated with a biodegradable-polymer sirolimus-eluting stent versus durable-polymer everolimus-eluting stents after rotational atherectomy.

Authors:  Nader Mankerious; Rayyan Hemetsberger; Hussein Traboulsi; Ralph Toelg; Mohamed Abdel-Wahab; Gert Richardt; Abdelhakim Allali
Journal:  Clin Res Cardiol       Date:  2021-04-16       Impact factor: 5.460

3.  Long-term follow-up after ultrathin vs. conventional 2nd-generation drug-eluting stents: a systematic review and meta-analysis of randomized controlled trials.

Authors:  Mahesh V Madhavan; James P Howard; Azim Naqvi; Ori Ben-Yehuda; Bjorn Redfors; Megha Prasad; Bahira Shahim; Martin B Leon; Sripal Bangalore; Gregg W Stone; Yousif Ahmad
Journal:  Eur Heart J       Date:  2021-07-15       Impact factor: 29.983

4.  Meta-analyses of moving targets.

Authors:  Colin Berry
Journal:  Eur Heart J       Date:  2021-07-15       Impact factor: 35.855

5.  Clinical outcomes of an ultrathin-strut sirolimus-eluting stent in all-comers population: Thailand Orsiro registry.

Authors:  Pannipa Suwannasom; Siriporn Athiksakul; Tasalak Thonghong; Vorarit Lertsuwunseri; Jarkarpun Chaipromprasit; Suphot Srimahachota; Wasan Udayachalerm; Srun Kuanprasert; Wacin Buddhari
Journal:  BMC Cardiovasc Disord       Date:  2021-10-16       Impact factor: 2.298

6.  Individual patient data analysis of the BIOFLOW study program comparing safety and efficacy of a bioresorbable polymer sirolimus eluting stent to a durable polymer everolimus eluting stent.

Authors:  Ralph Toelg; Ton Slagboom; Johannes Waltenberger; Thierry Lefèvre; Shigeru Saito; David E Kandzari; Jacques Koolen; Gert Richardt
Journal:  Catheter Cardiovasc Interv       Date:  2020-09-05       Impact factor: 2.585

7.  Ultrathin-strut biodegradable polymer versus durable polymer drug-eluting stents: a meta-analysis.

Authors:  Mohammad Riashad Monjur; Christian F Said; Paul Bamford; Michael Parkinson; Richard Szirt; Thomas Ford
Journal:  Open Heart       Date:  2020-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.