PURPOSE: Recently, a new Bayesian Penalized Likelihood (BPL) Reconstruction Algorithm was introduced by GE Healthcare, Q.Clear; it promises to provide better PET image resolution compared to the widely used Ordered Subset Expectation Maximization (OSEM). The aim of this study is to compare the performance of these two algorithms on several types of findings, in terms of image quality, lesion detectability, sensitivity, and specificity.
METHODS: Between September 6th 2017 and July 31st 2018, 663 whole body 18F-FDG PET/CT scans were performed at the Nuclear Medicine Department of S. Martino Hospital (Belluno, Italy). Based on the availability of clinical/radiological follow-up data, 240 scans were retrospectively reviewed. For each scan, a hypermetabolic finding was selected, reporting both for OSEM and Q.Clear: SUVmax and SUVmean values of the finding, the liver and the background close to the finding; size of the finding; percentage variations of SUVmax and SUVmean. Each finding was subsequently correlated with clinical and radiological follow-up, to define its benign/malignant nature.
RESULTS: Overall, Q.Clear improved the SUV values in each scan, especially in small findings (< 10 mm), high SUVmax values (≥ 10), and medium/low backgrounds. Furthermore, Q.Clear amplifies the signal of hypermetabolic findings without modifying the background signal, which leads to an increase in signal-to-noise ratio, improving overall image quality. Finally, Q.Clear did not affect PET sensitivity or specificity, in terms of number of reported findings and characterization of their nature.
CONCLUSIONS: Q.Clear is an iterative algorithm that improves significantly the quality of PET images compared to OSEM, increasing the SUVmax of findings (in particular for small findings) and the signal-to-noise ratio. However, due to the intrinsic characteristics of this algorithm, it will be necessary to adapt and/or modify the current interpretative criteria based of quantitative evaluation, to avoid an overestimation of the disease burden.

Entities:  

Keywords:  18FDG-PET; BPL reconstruction algorithm; OSEM; PET/CT; Q.Clear; Reconstruction algorithm

Year:  2019        PMID: 31231442      PMCID: PMC6554360          DOI: 10.1007/s13139-019-00594-x

Source DB:  PubMed          Journal:  Nucl Med Mol Imaging        ISSN: 1869-3474


  22 in total

Review 1.  PET instrumentation and reconstruction algorithms in whole-body applications.

Authors:  Gabriele Tarantola; Felicia Zito; Paolo Gerundini
Journal:  J Nucl Med       Date:  2003-05       Impact factor: 10.057

Review 2.  Recent Advances and Future Progress in PET Instrumentation.

Authors:  Piotr J Slomka; Tinsu Pan; Guido Germano
Journal:  Semin Nucl Med       Date:  2016-01       Impact factor: 4.446

Review 3.  System models for PET statistical iterative reconstruction: A review.

Authors:  A Iriarte; R Marabini; S Matej; C O S Sorzano; R M Lewitt
Journal:  Comput Med Imaging Graph       Date:  2015-12-19       Impact factor: 4.790

4.  Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET.

Authors:  Sangtae Ahn; Steven G Ross; Evren Asma; Jun Miao; Xiao Jin; Lishui Cheng; Scott D Wollenweber; Ravindra M Manjeshwar
Journal:  Phys Med Biol       Date:  2015-07-09       Impact factor: 3.609

5.  Recommendations for initial evaluation, staging, and response assessment of Hodgkin and non-Hodgkin lymphoma: the Lugano classification.

Authors:  Bruce D Cheson; Richard I Fisher; Sally F Barrington; Franco Cavalli; Lawrence H Schwartz; Emanuele Zucca; T Andrew Lister
Journal:  J Clin Oncol       Date:  2014-09-20       Impact factor: 44.544

6.  Does a novel penalized likelihood reconstruction of 18F-FDG PET-CT improve signal-to-background in colorectal liver metastases?

Authors:  Nassim Parvizi; James M Franklin; Daniel R McGowan; Eugene J Teoh; Kevin M Bradley; Fergus V Gleeson
Journal:  Eur J Radiol       Date:  2015-06-29       Impact factor: 3.528

Review 7.  Advances in time-of-flight PET.

Authors:  Suleman Surti; Joel S Karp
Journal:  Phys Med       Date:  2016-01-06       Impact factor: 2.685

8.  Novel penalised likelihood reconstruction of PET in the assessment of histologically verified small pulmonary nodules.

Authors:  Eugene J Teoh; Daniel R McGowan; Kevin M Bradley; Elizabeth Belcher; Edward Black; Fergus V Gleeson
Journal:  Eur Radiol       Date:  2015-05-20       Impact factor: 5.315

9.  Recent developments in time-of-flight PET.

Authors:  S Vandenberghe; E Mikhaylova; E D'Hoe; P Mollet; J S Karp
Journal:  EJNMMI Phys       Date:  2016-02-16

10.  Phantom and Clinical Evaluation of the Bayesian Penalized Likelihood Reconstruction Algorithm Q.Clear on an LYSO PET/CT System.

Authors:  Eugene J Teoh; Daniel R McGowan; Ruth E Macpherson; Kevin M Bradley; Fergus V Gleeson
Journal:  J Nucl Med       Date:  2015-07-09       Impact factor: 10.057

View more
  6 in total

1.  PET/CT Radiomic Features: A Potential Biomarker for EGFR Mutation Status and Survival Outcome Prediction in NSCLC Patients Treated With TKIs.

Authors:  Liping Yang; Panpan Xu; Mengyue Li; Menglu Wang; Mengye Peng; Ying Zhang; Tingting Wu; Wenjie Chu; Kezheng Wang; Hongxue Meng; Lingbo Zhang
Journal:  Front Oncol       Date:  2022-06-21       Impact factor: 5.738

2.  Can Q.Clear reconstruction be used to improve [68 Ga]Ga-DOTANOC PET/CT image quality in overweight NEN patients?

Authors:  Lucia Zanoni; Giulia Argalia; Emilia Fortunati; Claudio Malizia; Vincenzo Allegri; Diletta Calabrò; Simona Civollani; Davide Campana; Stefano Fanti; Valentina Ambrosini
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-10-25       Impact factor: 9.236

3.  Changes of [18F]FDG-PET/CT quantitative parameters in tumor lesions by the Bayesian penalized-likelihood PET reconstruction algorithm and its influencing factors.

Authors:  Yao Liu; Mei-Jia Gao; Jie Zhou; Fan Du; Liang Chen; Zhong-Ke Huang; Ji-Bo Hu; Cen Lou
Journal:  BMC Med Imaging       Date:  2021-09-16       Impact factor: 1.930

4.  Small lesion depiction and quantification accuracy of oncological 18F-FDG PET/CT with small voxel and Bayesian penalized likelihood reconstruction.

Authors:  Lei Xu; Ru-Shuai Li; Run-Ze Wu; Rui Yang; Qin-Qin You; Xiao-Chen Yao; Hui-Fang Xie; Yang Lv; Yun Dong; Feng Wang; Qing-Le Meng
Journal:  EJNMMI Phys       Date:  2022-03-26

5.  Radiomics in Gastric Cancer: First Clinical Investigation to Predict Lymph Vascular Invasion and Survival Outcome Using 18F-FDG PET/CT Images.

Authors:  Liping Yang; Wenjie Chu; Mengyue Li; Panpan Xu; Menglu Wang; Mengye Peng; Kezheng Wang; Lingbo Zhang
Journal:  Front Oncol       Date:  2022-03-30       Impact factor: 6.244

6.  Ordered subset expectation maximisation vs Bayesian penalised likelihood reconstruction algorithm in 18F-PSMA-1007 PET/CT.

Authors:  Ewa Witkowska-Patena; Anna Budzyńska; Agnieszka Giżewska; Mirosław Dziuk; Agata Walęcka-Mazur
Journal:  Ann Nucl Med       Date:  2020-01-04       Impact factor: 2.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.