Literature DB >> 31229677

Electrocardiographic and clinical predictors of permanent pacemaker insertion following Perceval sutureless aortic valve implantation.

Giacomo Mugnai1, Darragh Moran2, Jan Nijs3, Gian-Battista Chierchia2, Vedran Velagic2, Erwin Ströker2, Burak Hunuk2, Jens Czapla3, Pedro Brugada2, Mark La Meir3, Carlo de Asmundis2.   

Abstract

BACKGROUND: Sutureless aortic valve replacement surgery (AVR) is a reasonable alternative surgical approach in those patients with aortic stenosis who would benefit from reduced cross clamp time, such as elderly and high-risk patients. We sought to evaluate the incidence of pacemaker (PM) implantation following sutureless AVR and to analyse possible pre-operative electrocardiographic and clinical predictors of PM implantation. METHODS AND
RESULTS: Between November 2013 and March 2015, 58 patients (male 43%, age 77.9 ± 4.9 years) having undergone sutureless AVR with a Perceval prosthesis (Sorin Biomedica Cardio Srl, Saluggia, Italy) were taken into consideration for our analysis. During a mean follow up of 13.8 ± 5.0 months (median 13 months), 14 patients (24.1%) underwent pacemaker (PM) implantation following sutureless AVR procedure. Among these patients, 12 (86%) presented III degree atrioventricular (AV) block, 1 (7%) presented II degree AV block, and remaining one (7%) severe symptomatic bradycardia. The comparison of pre-operative characteristics between PM group and no PM group highlighted that QRS duration, EuroSCORE II index and chronic renal dysfunction were significantly associated with the development of AV conduction abnormalities/symptomatic bradycardia requiring PM implantation (respectively, p = 0.01, p = 0.02 and p = 0.03).
CONCLUSIONS: The incidence of PM implantation after sutureless AVR was 24.1% in the present study. The EuroSCORE II, QRS duration and renal dysfunction were significantly associated with higher risk of AV conduction abnormalities/symptomatic bradycardia requiring PM placement.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Aortic stenosis; Pacemaker; QRS duration; Sutureless aortic valve replacement

Mesh:

Year:  2019        PMID: 31229677     DOI: 10.1016/j.jelectrocard.2019.06.004

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  3 in total

1.  Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively.

Authors:  Delphine Szecel; Marie Lamberigts; Filip Rega; Peter Verbrugghe; Christophe Dubois; Bart Meuris
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-07-09

2.  Recent improvement in operative techniques lead to lower pacemaker rate after Perceval implant.

Authors:  Olivier Fabre; Mihai Radutoiu; Ionut Carjaliu; Olivier Rebet; Laurence Gautier; Ilir Hysi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2022-07-09

3.  A pooled analysis of pacemaker implantation after Perceval sutureless aortic valve replacement.

Authors:  Marco Moscarelli; Giuseppe Santarpino; Thanos Athanasiou; Pasquale Mastroroberto; Khalil Fattouch; Giuseppe Nasso; Giuseppe Speziale
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-10-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.