Literature DB >> 31228854

Label-free discrimination of single nucleotide changes in DNA by reflectometric interference Fourier transform spectroscopy.

Farideh Makiyan1, Fereshteh Rahimi2, Marziyeh Hajati1, Azizollah Shafiekhani3, Ali Hossein Rezayan1, Naser Ansari-Pour4.   

Abstract

Phenotypic variation - such as disease susceptibility and differential drug response - has a strong genetic component. Substantial effort has therefore been made to identify causal genomic variants explaining such variation among humans. Point mutations (PMs), which are single nucleotide changes in the genome, have been identified to be the most abundant form of causal genomic variants, making them useful, reliable diagnostic markers. Methods developed to genotype PMs have moved towards solid-phase assays, which not only show greater sensitivity and specificity, but also enable scalability and faster processing time. Most current assays are, however, based on fluorescent probes, which makes them relatively expensive. To develop a more cost-effective label-free genotyping method, we used a porous silicon (PSi) base as an efficient support for DNA biosensing and coupled it with reflectometric interference Fourier transform spectroscopy (RIFTS). To assess the versatility of this approach, we tested both a single nucleotide substitution in VKORC1 (-1639G > A; rs9923231) and a single nucleotide insertion in BRCA1 (5382insC; rs80357906). We demonstrate that the PSi-RIFTS method can efficiently detect both PM types with high sensitivity where hybridization of complementary DNA can be quantifiably differentiated from mismatch and non-complementary hybridization events. In addition, we show that the PSi base with immobilized DNA not only can be re-used to type further samples, but it also remains stable for 14 days, suggesting its potential for high-throughput applications.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  DNA biosensing; Genetic variation; Genotyping; Porous silicon; Reflectometric interference Fourier transform spectroscopy

Year:  2019        PMID: 31228854     DOI: 10.1016/j.colsurfb.2019.05.066

Source DB:  PubMed          Journal:  Colloids Surf B Biointerfaces        ISSN: 0927-7765            Impact factor:   5.268


  2 in total

Review 1.  Recent Progress in Optical Sensors for Biomedical Diagnostics.

Authors:  Muqsit Pirzada; Zeynep Altintas
Journal:  Micromachines (Basel)       Date:  2020-03-30       Impact factor: 2.891

2.  A lectin-coupled porous silicon-based biosensor: label-free optical detection of bacteria in a real-time mode.

Authors:  Mona Yaghoubi; Fereshteh Rahimi; Babak Negahdari; Ali Hossein Rezayan; Azizollah Shafiekhani
Journal:  Sci Rep       Date:  2020-09-29       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.