Comparison of different devices to measure the intraocular pressure in thyroid-associated orbitopathy.

Aylin Garip Kuebler1, Caroline Wiecha2, Lukas Reznicek3, Annemarie Klingenstein2, Kathrin Halfter4, Siegfried Priglinger2, Christoph Hintschich2.   

Abstract

PURPOSE: To evaluate the correlation of the intraocular pressure measurements (IOP) with non-contact tonometer Corvis Scheimpflug technology (Corvis ST), Goldmann applanation tonometry (GAT), ocular response analyzer (ORA), and iCARE rebound tonometer in patients with thyroid-associated orbitopathy (TAO) and eye-healthy subjects (control group).
METHODS: Twenty-nine consecutive patients with TAO (79% female) and 30 eye-healthy subjects (60% female) were included in this prospective, age- and sex-matched study. The IOP measurement with Corvis, ORA, GAT, iCARE, and central corneal thickness (CCT) with Corvis was obtained from all study participants.
RESULTS: The mean age of the patients was 51 ± 10 years in patients with TAO and 56 ± 13 years in the control group. The mean IOP measurements with GAT, Corvis, ORA, and iCARE were 15.93 ± 4.42 mmHg, 18.10 ± 7.54 mmHg, 18.40 ± 7.93 mmHg, and 16.61 ± 7.96 mmHg in patients with TAO and 14.52 ± 3.02 mmHg, 14.48 ± 3.38 mmHg, 15.29 ± 4.64 mmHg, and 14.13 ± 3.85 mmHg in the control group (P = 0.157, P = 0.004, P = 0.017, and P = 0.176 respectively). The mean CCT was 547.5 ± 39.2 μm in patients with TAO and 560.8 ± 49.8 μm in the control group ( P= 0.261).
CONCLUSIONS: The data collected shows an agreement between the iCARE and GAT IOP measurements in TAO patients and in eye-healthy patients. However, the mean value of IOP measurements with Corvis and ORA was significantly higher in patients with TAO in comparison with the control group (P = 0.044 and P = 0.029 respectively).

Entities:  

Keywords:  Corvis ST; Goldmann applanation tonometry; Intraocular pressure; ORA; Thyroid-associated orbitopathy; iCARE

Mesh:

Year:  2019        PMID: 31222404     DOI: 10.1007/s00417-019-04367-2

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  5 in total

1.  Comparison of Two Tonometers in the Evaluation of 24-Hour Intraocular Pressure and Mean Ocular Perfusion Pressure in Patients with Thyroid-Associated Ophthalmopathy.

Authors:  Weijie Liu; Yao Zhou; Xiaozhou Hu; Haochen Jin; Jie Ye; Mingna Xu; Zihui Liu; Wencan Wu; Yunhai Tu
Journal:  J Ophthalmol       Date:  2022-04-22       Impact factor: 1.974

2.  Correlation Analysis between Intraocular Pressure and Extraocular Muscles Based on Orbital Magnetic Resonance T2 Mapping in Thyroid-Associated Ophthalmopathy Patients.

Authors:  Ban Luo; Wei Wang; Xinyu Li; Hong Zhang; Yaoli Zhang; Weikun Hu
Journal:  J Clin Med       Date:  2022-07-08       Impact factor: 4.964

3.  Influence of Corneal Visualization Scheimpflug Technology Tonometry on Intraocular Pressure.

Authors:  Davide Borroni; Kunal Ajit Gadhvi; Rozaliya Hristova; Keri McLean; Carlos Rocha de Lossada; Vito Romano; Stephen Kaye
Journal:  Ophthalmol Sci       Date:  2021-01-13

4.  The Effect of Thyroid Eye Disease on Corneal Biomechanical Properties.

Authors:  Melis Cansu Comert; Sezen Yilmaz; Ayse Yildiz Tas; Afsun Sahin
Journal:  Beyoglu Eye J       Date:  2022-08-05

5.  The Role of Corneal Biomechanics for the Evaluation of Ectasia Patients.

Authors:  Marcella Q Salomão; Ana Luisa Hofling-Lima; Louise Pellegrino Gomes Esporcatte; Bernardo Lopes; Riccardo Vinciguerra; Paolo Vinciguerra; Jens Bühren; Nelson Sena; Guilherme Simões Luz Hilgert; Renato Ambrósio
Journal:  Int J Environ Res Public Health       Date:  2020-03-23       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.