Literature DB >> 31219967

First MRI With New Cochlear Implant With Rotatable Internal Magnet System and Proposal for Standardization of Reporting Magnet-Related Artifact Size.

Nathan D Cass1, Justin M Honce2, Alexandra L O'Dell3, Samuel P Gubbels1.   

Abstract

OBJECTIVE: To report on the first known magnetic resonance imaging (MRI) with a new cochlear implant (CI) with rotatable internal magnet system, to review the literature on MRI in cochlear implantees, and to advocate for standardization of reporting magnet-related artifact size. STUDY
DESIGN: Case report and review of literature.
SETTING: Tertiary care hospital.
RESULTS: A patient with congenital rubella and bilateral profound hearing loss was incidentally found to have a petroclival meningioma. After resection and radiosurgery, she underwent cochlear implantation with the Advanced Bionics HiRes Ultra 3D device (Advanced Bionics LLC, Valencia, CA) with rotatable internal magnet system, due to need for imaging surveillance of residual meningioma. During 1.5 T MRI brain scan without a head wrap, she experienced no adverse events. The images obtained were adequate for visualization of residual tumor. Implant recipients with non-rotatable magnets who undergo MRI, with or without recommended head wrap, may suffer various complications. All images in patients with retained internal magnets are subject to magnet-related artifact, but reports regarding its size are variable and lack detail on how measurements are made.
CONCLUSIONS: MRI in patients with a new CI device with rotatable magnet system may be performed without discomfort or device dislodgement at 1.5 T, even without a head wrap, though external magnet replacement may require multiple attempts due to internal magnet realignment. Despite significant artifact, the structure of interest may still be visualized for accurate diagnosis. Measuring magnet-related artifact size should be standardized by reporting artifact in radii at the image level of maximal signal loss.

Entities:  

Mesh:

Year:  2019        PMID: 31219967     DOI: 10.1097/MAO.0000000000002269

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  6 in total

1.  Comparison of bandaging techniques to prevent cochlear implant magnet displacement following MRI.

Authors:  Martin Leinung; Andreas G Loth; Michaela Kroth; Iris Burck; Timo Stöver; Silke Helbig
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-01-02       Impact factor: 2.503

2.  Subtotal Petrosectomy and Cochlear Implantation: A Systematic Review and Meta-analysis.

Authors:  Flora Yan; Priyanka D Reddy; Mitchell J Isaac; Shaun A Nguyen; Theodore R McRackan; Ted A Meyer
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2020-10-15       Impact factor: 6.223

3.  MRI-induced artifact by a cochlear implant with a novel magnet system: an experimental cadaver study.

Authors:  Pietro Canzi; Federico Aprile; Anna Simoncelli; Marco Manfrin; Marianna Magnetto; Elvis Lafe; Domenico Minervini; Irene Avato; Simone Terrani; Andrea Scribante; Dzemal Gazibegovic; Marco Benazzo
Journal:  Eur Arch Otorhinolaryngol       Date:  2020-11-18       Impact factor: 2.503

4.  Magnet and receiver-stimulator displacement after cochlear implantation: Clinical characters and management approaches.

Authors:  Asma Alahmadi; Saad Alenzi; Mohammed Alsheikh; Saeed Alghamdi; Mostafa E Morra; Khalid M Badr
Journal:  Saudi Med J       Date:  2021-08       Impact factor: 1.422

Review 5.  Safety of active auditory implants in magnetic resonance imaging.

Authors:  Guy Fierens; Nina Standaert; Ronald Peeters; Christ Glorieux; Nicolas Verhaert
Journal:  J Otol       Date:  2021-01-06

6.  The role of cochlear implant positioning on MR imaging quality: a preclinical in vivo study with a novel implant magnet system.

Authors:  Pietro Canzi; Marianna Magnetto; Anna Simoncelli; Marco Manfrin; Federico Aprile; Elvis Lafe; Elena Carlotto; Irene Avato; Andrea Scribante; Lorenzo Preda; Marco Benazzo
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-08-09       Impact factor: 2.503

  6 in total