Christina L Goldstein1, Troy D Pashuck1, Kevin L Ingalls1, Laura L Billings1, Mohammad T Agha1, Mark W Drymalski1, Theodore J Choma1, Joel T Jeffries2, Christopher R James1.
Abstract
STUDYEntities:
Keywords: cervical; contrast dispersal; epidural steroid injection; magnetic resonance imaging
Year: 2019 PMID: 31218197 PMCID: PMC6562211 DOI: 10.1177/2192568218811141
Source DB: PubMed Journal: Global Spine J ISSN: 2192-5682
Figure 1.Sagittal MRI image showing gadolinium-enhanced contrast dispersion. Cranial epidural extent was at the level of the posterior arch of C1. Caudal epidural extent was to the T5 inferior endplate, which was better viewed on a subsequent sagittal slice.
Figure 2.Axial MRI image at the level of the C3 body demonstrating circumferential contrast dispersion. This image is of the same patient in Figure 1.
Gadolinium-Enhanced Injectate Migration Data.
| Patients | Cranial Migration (Level) | Caudal Migration (Level) | Cranial Migration (cm) | Caudal Migration (cm) | Craniocaudal Extent (cm) | Craniocaudal Extent (Levels) | Circumferential (°) |
|---|---|---|---|---|---|---|---|
| 1a | C3 superior endplate | Mid T2 body | 7.8 | 2.9 | 10.7 | 6.5 | 360 |
| 2 | C3 superior endplate | At least T4 inferior endplate | 8.1 | 8.9b | 17b | 9 | 360 |
| 3 | C3 superior endplate | T3 inferior endplate | 7.9 | 5.1 | 13 | 8 | 360 |
| 4 | C1 posterior arch | T5 inferior endplate | 8.9 | 9.8 | 18.7 | 12 | 360 |
| 5c | C1 posterior arch | T4 inferior endplate | 10.7 | 7.9 | 18.6 | 11 | 360 |
| 6 | C1 posterior arch | C7 inferior endplate | 9.3 | 0 | 9.3 | 7 | 360 |
| 7c | C4 superior endplate | At least T5 inferior endplate | 5.4 | 9.8b | 15.2b | 9 | 360 |
| 8c | C1 posterior arch | T2 inferior endplate | 9.1 | 3.4 | 12.5 | 9 | 360 |
| 9 | Base of dens | At least mid-T5 body | 8.9 | 9.2b | 18.1b | 11 | 360 |
| 10c | C1 posterior arch | T2 superior endplate | 7.8 | 1.7 | 9.5 | 8 | 360 |
| 11 | C3 superior endplate | At least T5 inferior endplate | 6.7 | 10.4b | 17.1b | 10 | 360 |
| 12a | C3 superior endplate | T4 inferior endplate | 8.7 | 9.1 | 17.8 | 9 | 360 |
| 13 | C5 inferior endplate | At least mid-T5 body | 3.3 | 10.7b | 14b | 7 | 360 |
| 14 | C2 inferior endplate | T4 inferior endplate | 8.7 | 8.5 | 17.2 | 9 | 360 |
| 15c | C1 posterior arch | T2 inferior endplate | 10.7 | 4.4 | 15.1 | 9 | 360 |
| 16a | C2 inferior endplate | T2 inferior endplate | 7.7 | 4.2 | 11.9 | 7 | 360 |
| Mean values | — | — | 8.11 | 6.63 | 14.73 | 8.84 | 360 |
a The injection was partially supra-ligamentous.
b The injectate dispersal traveled past magnetic resonance imaging (MRI) field of view in the inferior direction. These values are listed as the most inferior measurement on the MRI field of view for statistical purposes.
c The patient underwent anterior cervical discectomy and fusion surgery within 6 months of cervical epidural steroid injection.