Literature DB >> 3121209

Expired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation.

C V Gudipati1, M H Weil, J Bisera, H G Deshmukh, E C Rackow.   

Abstract

End-tidal CO2 concentration (ETCO2) may serve as a simple noninvasive measurement of the blood flow generated by precordial compression during cardiopulmonary resuscitation (CPR). In a mechanically ventilated porcine preparation of ventricular fibrillation, onset of fibrillation was associated with a rapid decrease in ETCO2 from 4.0 +/- 0.2% to less than 0.7 +/- 0.2%. With precordial compression, it increased to 1.9 +/- 0.3%. Animals that were successfully defibrillated after 12 min of CPR demonstrated an immediate increase in ETCO2. The ETCO2 increased from 1.9 +/- 0.3% to 4.9 +/- 0.3% over an interval of between 30 and 60 sec. These changes in ETCO2 were closely related to proportionally similar decreases and increases in cardiac output (CO), and a close correlation between ETCO2 and CO was demonstrated (r = .92). A similar highly significant correlation between ETCO2 and CO was also demonstrated during open-chest cardiac massage (r = .95). ETCO2 therefore serves as a noninvasive measure of pulmonary blood flow and therefore CO. In 17 successfully resuscitated animals. ETCO2 during precordial compression averaged 1.7 +/- 0.2%, whereas it was only 0.5 +/- 0.1% in five animals in whom resuscitation procedures were unsuccessful (p less than .001). Accordingly, ETCO2 prognosticates outcome during CPR and immediately identifies restoration of spontaneous circulation.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3121209     DOI: 10.1161/01.cir.77.1.234

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  38 in total

1.  End-tidal CO₂ detection of an audible heart rate during neonatal cardiopulmonary resuscitation after asystole in asphyxiated piglets.

Authors:  Lina F Chalak; Chad A Barber; Linda Hynan; Damian Garcia; Lucy Christie; Myra H Wyckoff
Journal:  Pediatr Res       Date:  2011-05       Impact factor: 3.756

2.  Sensitivity of a disposable end-tidal carbon dioxide detector.

Authors:  B R Jones; M J Dorsey
Journal:  J Clin Monit       Date:  1991-07

3.  Measuring exhaled carbon dioxide in cardiac arrest.

Authors:  M Callaham
Journal:  West J Med       Date:  1989-07

4.  Cardiopulmonary resuscitation with active compression-decompression.

Authors:  C F Weston
Journal:  Br Heart J       Date:  1995-09

5.  A quantitative comparison of physiologic indicators of cardiopulmonary resuscitation quality: Diastolic blood pressure versus end-tidal carbon dioxide.

Authors:  Ryan W Morgan; Benjamin French; Todd J Kilbaugh; Maryam Y Naim; Heather Wolfe; George Bratinov; Wesley Shoap; Ting-Chang Hsieh; Vinay M Nadkarni; Robert A Berg; Robert M Sutton
Journal:  Resuscitation       Date:  2016-04-20       Impact factor: 5.262

6.  Value of capnography to predict defibrillation success in out-of-hospital cardiac arrest.

Authors:  Beatriz Chicote; Elisabete Aramendi; Unai Irusta; Pamela Owens; Mohamud Daya; Ahamed Idris
Journal:  Resuscitation       Date:  2019-03-02       Impact factor: 5.262

7.  Mechanics of the circulation during cardiopulmonary resuscitation. Pathophysiology and techniques (Part II).

Authors:  J Peters; P Ihle
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

Review 8.  Protecting mitochondrial bioenergetic function during resuscitation from cardiac arrest.

Authors:  Raúl J Gazmuri; Jeejabai Radhakrishnan
Journal:  Crit Care Clin       Date:  2012-04       Impact factor: 3.598

9.  The Effect of Asphyxia Arrest Duration on a Pediatric End-Tidal CO2-Guided Chest Compression Delivery Model.

Authors:  Jennifer L Hamrick; Justin T Hamrick; Caitlin E O'Brien; Michael Reyes; Polan T Santos; Sophie E Heitmiller; Ewa Kulikowicz; Jennifer K Lee; Sapna R Kudchadkar; Raymond C Koehler; Elizabeth A Hunt; Donald H Shaffner
Journal:  Pediatr Crit Care Med       Date:  2019-07       Impact factor: 3.624

10.  End tidal carbon dioxide as a predictor of the arterial PCO2 in the emergency department setting.

Authors:  C Yosefy; E Hay; Y Nasri; E Magen; L Reisin
Journal:  Emerg Med J       Date:  2004-09       Impact factor: 2.740

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.