Literature DB >> 31206701

Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network.

Anna M Dinkla1,2, Mateusz C Florkow3, Matteo Maspero1,2, Mark H F Savenije1,2, Frank Zijlstra3, Patricia A H Doornaert1, Marijn van Stralen3,4, Marielle E P Philippens1, Cornelis A T van den Berg1,2, Peter R Seevinck3,4.   

Abstract

PURPOSE: To develop and evaluate a patch-based convolutional neural network (CNN) to generate synthetic computed tomography (sCT) images for magnetic resonance (MR)-only workflow for radiotherapy of head and neck tumors. A patch-based deep learning method was chosen to improve robustness to abnormal anatomies caused by large tumors, surgical excisions, or dental artifacts. In this study, we evaluate whether the generated sCT images enable accurate MR-based dose calculations in the head and neck region.
METHODS: We conducted a retrospective study on 34 patients with head and neck cancer who underwent both CT and MR imaging for radiotherapy treatment planning. To generate the sCTs, a large field-of-view T2-weighted Turbo Spin Echo MR sequence was used from the clinical protocol for multiple types of head and neck tumors. To align images as well as possible on a voxel-wise level, CT scans were nonrigidly registered to the MR (CTreg ). The CNN was based on a U-net architecture and consisted of 14 layers with 3 × 3 × 3 filters. Patches of 48 × 48 × 48 were randomly extracted and fed into the training. sCTs were created for all patients using threefold cross validation. For each patient, the clinical CT-based treatment plan was recalculated on sCT using Monaco TPS (Elekta). We evaluated mean absolute error (MAE) and mean error (ME) within the body contours and dice scores in air and bone mask. Also, dose differences and gamma pass rates between CT- and sCT-based plans inside the body contours were calculated.
RESULTS: sCT generation took 4 min per patient. The MAE over the patient population of the sCT within the intersection of body contours was 75 ± 9 Hounsfield Units (HU) (±1 SD), and the ME was 9 ± 11 HU. Dice scores of the air and bone masks (CTreg vs sCT) were 0.79 ± 0.08 and 0.70 ± 0.07, respectively. Dosimetric analysis showed mean deviations of -0.03% ± 0.05% for dose within the body contours and -0.07% ± 0.22% inside the >90% dose volume. Dental artifacts obscuring the CT could be circumvented in the sCT by the CNN-based approach in combination with Turbo Spin Echo (TSE) magnetic resonance imaging (MRI) sequence that typically is less prone to susceptibility artifacts.
CONCLUSIONS: The presented CNN generated sCTs from conventional MR images without adding scan time to the acquisition. Dosimetric evaluation suggests that dose calculations performed on the sCTs are accurate, and can therefore be used for MR-only radiotherapy treatment planning of the head and neck.
© 2019 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

Entities:  

Keywords:  MR-guided therapy; MR-only radiotherapy; deep learning; head and neck cancer; synthetic CT

Mesh:

Year:  2019        PMID: 31206701     DOI: 10.1002/mp.13663

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  13 in total

1.  Synthetic Computed Tomography Generation from 0.35T Magnetic Resonance Images for Magnetic Resonance-Only Radiation Therapy Planning Using Perceptual Loss Models.

Authors:  Xue Li; Poonam Yadav; Alan B McMillan
Journal:  Pract Radiat Oncol       Date:  2021-08-24

2.  Clinical application of deep learning-based synthetic CT from real MRI to improve dose planning accuracy in Gamma Knife radiosurgery: a proof of concept study.

Authors:  So Hee Park; Dong Min Choi; In-Ho Jung; Kyung Won Chang; Myung Ji Kim; Hyun Ho Jung; Jin Woo Chang; Hwiyoung Kim; Won Seok Chang
Journal:  Biomed Eng Lett       Date:  2022-06-13

Review 3.  Target Definition in MR-Guided Adaptive Radiotherapy for Head and Neck Cancer.

Authors:  Mischa de Ridder; Cornelis P J Raaijmakers; Frank A Pameijer; Remco de Bree; Floris C J Reinders; Patricia A H Doornaert; Chris H J Terhaard; Marielle E P Philippens
Journal:  Cancers (Basel)       Date:  2022-06-20       Impact factor: 6.575

Review 4.  A Survey on Deep Learning for Precision Oncology.

Authors:  Ching-Wei Wang; Muhammad-Adil Khalil; Nabila Puspita Firdi
Journal:  Diagnostics (Basel)       Date:  2022-06-17

5.  Convolutional neural network enhancement of fast-scan low-dose cone-beam CT images for head and neck radiotherapy.

Authors:  Nimu Yuan; Brandon Dyer; Shyam Rao; Quan Chen; Stanley Benedict; Lu Shang; Yan Kang; Jinyi Qi; Yi Rong
Journal:  Phys Med Biol       Date:  2020-01-27       Impact factor: 3.609

Review 6.  A review on medical imaging synthesis using deep learning and its clinical applications.

Authors:  Tonghe Wang; Yang Lei; Yabo Fu; Jacob F Wynne; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  J Appl Clin Med Phys       Date:  2020-12-11       Impact factor: 2.102

7.  Synthetic computed tomography data allows for accurate absorbed dose calculations in a magnetic resonance imaging only workflow for head and neck radiotherapy.

Authors:  Emilia Palmér; Anna Karlsson; Fredrik Nordström; Karin Petruson; Carl Siversson; Maria Ljungberg; Maja Sohlin
Journal:  Phys Imaging Radiat Oncol       Date:  2021-01-11

8.  Robustness and Generalizability of Deep Learning Synthetic Computed Tomography for Positron Emission Tomography/Magnetic Resonance Imaging-Based Radiation Therapy Planning of Patients With Head and Neck Cancer.

Authors:  Anders B Olin; Christopher Thomas; Adam E Hansen; Jacob H Rasmussen; Georgios Krokos; Teresa Guerrero Urbano; Andriana Michaelidou; Björn Jakoby; Claes N Ladefoged; Anne K Berthelsen; Katrin Håkansson; Ivan R Vogelius; Lena Specht; Sally F Barrington; Flemming L Andersen; Barbara M Fischer
Journal:  Adv Radiat Oncol       Date:  2021-07-26

9.  Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis.

Authors:  Jens M Edmund; Daniel Andreasen; Koen Van Leemput
Journal:  Phys Imaging Radiat Oncol       Date:  2021-05-13

Review 10.  Medical physics challenges in clinical MR-guided radiotherapy.

Authors:  Christopher Kurz; Giulia Buizza; Guillaume Landry; Florian Kamp; Moritz Rabe; Chiara Paganelli; Guido Baroni; Michael Reiner; Paul J Keall; Cornelis A T van den Berg; Marco Riboldi
Journal:  Radiat Oncol       Date:  2020-05-05       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.