A biomechanical comparison between human calvarial bone and a skull simulant considering the role of attached periosteum and dura mater.

Benjamin Ondruschka1, Jik Hang Clifford Lee2, Mario Scholze3,4, Johann Zwirner4, Darryl Tong5, John Neil Waddell2,6, Niels Hammer4,7,8.   

Abstract

PURPOSE: Current forensic analysis of blunt force trauma relies on the use of cadaveric or animal tissues, posing ethical and reproducibility concerns. Artificial substitutes may help overcome such issues. However, existing substitutes exhibit poor anatomic and mechanical biofidelity, especially in the choice of skull simulant material. Progress has been made in identifying materials that have similar mechanical properties to the human skull bone, with the potential to behave similarly in mechanical loading. AIMS: To compare the biomechanical properties of the human calvarial bone with an epoxy resin-based simulant material. Data collected was also used to analyse the effect of periosteal attachment on the mechanical properties of skull bone compared with that of the counterpart samples.
METHODS: Fifty-six human skull bone specimens were prepared from two cadaveric heads. Half of these specimens were removed of periosteum and dura mater as the PR (periosteum removed) group, whereas periosteum was left attached in the PA (periosteum attached) group. Duplicates of the bone specimens were fabricated out of an epoxy resin and paired in corresponding PR and PA groups. The specimens were loaded under three-point bending tests until fracture with image-based deformation detection.
RESULTS: Comparison of the epoxy resin and skull specimens yielded similarity for both the PR and PA groups, being closer to the PA group (bending modulus resin PR 2665 MPa vs. skull PR 1979 MPa, resin PA 3165 MPa vs. skull PA 3330 MPa; maximum force resin PR 574 N vs. skull PR 728 N, resin PA 580 N vs. skull PA 1034 N; strain at maximum force resin PR 2.7% vs. skull PR 5.1%, resin PA 2.3% vs. skull PA 3.5%, deflection at maximum force resin PR 0.5 mm vs. skull PR 0.8 mm, resin PA 0.5 mm vs. skull PA 1.0 mm). Bending strength was significantly lower in the resin groups (resin PR 43 MPa vs. skull PR 55 MPa, resin PA 44 MPa vs. skull PA 75 MPa). Moreover, the correlations of the mechanical data exhibited closer accordance of the PR group with the epoxy resin compared with the PA group with the epoxy resin.
CONCLUSIONS: The load-deformation properties of the epoxy resin samples assessed in this study fell within a closer range to the skull specimens with PR  than with PA. Moreover, the values obtained for the resin fall within the reference range for skull tissues in the literature suggesting that the proposed epoxy resin may provide a usable artificial substitute for PA but does not totally represent the human skull in its complex anatomical structure.

Entities:  

Keywords:  Digital image correlation; Dura mater; Epoxy resin; Human skull bone; Periosteum; Skull simulant

Mesh:

Substances:

Year:  2019        PMID: 31203433     DOI: 10.1007/s00414-019-02102-4

Source DB:  PubMed          Journal:  Int J Legal Med        ISSN: 0937-9827            Impact factor:   2.686


  4 in total

1.  The dynamic impact behavior of the human neurocranium.

Authors:  Johann Zwirner; Benjamin Ondruschka; Mario Scholze; Joshua Workman; Ashvin Thambyah; Niels Hammer
Journal:  Sci Rep       Date:  2021-05-31       Impact factor: 4.379

2.  Topographical mapping of the mechanical characteristics of the human neurocranium considering the role of individual layers.

Authors:  Johann Zwirner; Sarah Safavi; Mario Scholze; Kai Chun Li; John Neil Waddell; Björn Busse; Benjamin Ondruschka; Niels Hammer
Journal:  Sci Rep       Date:  2021-02-12       Impact factor: 4.379

3.  Biomechanical Evaluation of Patient-Specific Polymethylmethacrylate Cranial Implants for Virtual Surgical Planning: An In-Vitro Study.

Authors:  Bilal Msallem; Michaela Maintz; Florian S Halbeisen; Simon Meyer; Guido R Sigron; Neha Sharma; Shuaishuai Cao; Florian M Thieringer
Journal:  Materials (Basel)       Date:  2022-03-07       Impact factor: 3.623

4.  What is Considered a Variation of Biomechanical Parameters in Tensile Tests of Collagen-Rich Human Soft Tissues? - Critical Considerations Using the Human Cranial Dura Mater as a Representative Morpho-Mechanic Model.

Authors:  Johann Zwirner; Mario Scholze; Benjamin Ondruschka; Niels Hammer
Journal:  Medicina (Kaunas)       Date:  2020-10-05       Impact factor: 2.430

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.