Literature DB >> 31201508

Histologic Analysis with the Newly Designed Exoskeleton Seal® Stent-Graft in the Porcine Abdominal Aorta.

Jung-Hoon Park1, Young Kwon Cho2, Keun Her3, Yong Sun Jeon4, Jeong Ho Kim5, Tae-Seok Seo6, Myung Gyu Song6.   

Abstract

PURPOSE: To investigate the technical feasibility of a novel exoskeleton Seal® stent-graft and analyze early histologic changes in the porcine abdominal aorta.
MATERIALS AND METHODS: Six pigs received an abdominal stent-graft (Group I), and six received an iliac branch stent-graft (Group II). Groups were subdivided as follows: Group Ia, which received three bifurcated main-body stent-grafts; Group Ib, which received three bifurcated main-body stent-grafts with both iliac graft-stents; Group IIa, which received three simple uni-iliac tapered stent-grafts; and Group IIb, which received three uni-iliac tapered tapered stent-grafts with right straight limb and left branched limb. Statistical analyses were performed with the Wilcoxon signed-rank test and mixed-model regression analysis.
RESULTS: The primary technical success rate (< 24 h) was 83% because of two acute thromboses in the lumen of the stented abdominal aorta immediately after stent-graft placement. At 4 weeks, late thrombosis occurred in two pigs. Higher mean neointimal hyperplasia areas (23.5% vs. 16.2%; P = .047), neointimal hyperplasia thicknesses (545.5 μm vs. 422.2 μm; P = .001), and degrees of collagen deposition (2.71 vs. 2.33; P = .002) were observed at the bare-metal stent-graft compared with the proximal exoskeleton portion of the stent-graft, with no significant differences between the patent and occluded groups or among the four types of stent-grafts.
CONCLUSIONS: The exoskeleton stent-graft demonstrates 66% of patency rate during 1-month follow-up due to four cases of thromboses; however, the endothelialization on the junction of proximal graft showed no significant differences between the patent and occluded groups. Further studies should investigate long-term outcomes with prolonged neointimal hyperplasia.

Entities:  

Keywords:  Animal studies; Exoskeleton stent-graft; Neointimal hyperplasia; Porcine abdominal aorta; Thrombotic occlusions

Mesh:

Year:  2019        PMID: 31201508     DOI: 10.1007/s00270-019-02261-2

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  1 in total

1.  Efficacy of thermoplastic polyurethane and gelatin blended nanofibers covered stent graft in the porcine iliac artery.

Authors:  Dae Sung Ryu; Dong-Sung Won; Ji Won Kim; Yubeen Park; Song Hee Kim; Jeon Min Kang; Chu Hui Zeng; Dohyung Lim; Hyun Choi; Jung-Hoon Park
Journal:  Sci Rep       Date:  2022-10-03       Impact factor: 4.996

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.