Abstract

In this study the evolution in the efficiency of electrochemotherapy (reversible electroporation) with pulse number was assessed in vitro. Experiments were performed using 100 μs pulses at different electric field intensities and the chemotherapeutic agent bleomycin. Additionally, electrical impedance spectroscopy measurements were used as a different method to study in real time the changes produced on cells with pulse number during trains of consecutive pulses. Our results show that the relation between pulse number and the observed outcome is complex and difficult to fully characterize. This relation can display a highly linear behaviour up to a certain number of pulses and/or field intensity applied. However, the relation between the number of pulses and the observed outcome always evolves to a saturation or at least a reduction in the electric field effects that is displayed when either electric field intensity or pulse number are increased. An exponential model was found to best describe this relation within the range of experimental conditions considered. Electrical impedance measurements confirmed the results and gave a more precise quantification of this dependence. The study highlights the importance that pulse number has in the electrochemotherapy protocols and establishes some limits in the use of this parameter.
Copyright © 2019. Published by Elsevier B.V.

Entities:  

Keywords:  Electrochemotherapy; Number of pulses; Reversible electroporation; Saturation

Mesh:

Substances:

Year:  2019        PMID: 31200252     DOI: 10.1016/j.bioelechem.2019.05.021

Source DB:  PubMed          Journal:  Bioelectrochemistry        ISSN: 1567-5394            Impact factor:   5.373


  4 in total

1.  Real-Time Impedance Monitoring During Electroporation Processes in Vegetal Tissue Using a High-Performance Generator.

Authors:  Borja López-Alonso; Hector Sarnago; Oscar Lucía; Pablo Briz; José Miguel Burdío
Journal:  Sensors (Basel)       Date:  2020-06-02       Impact factor: 3.576

2.  10 ns PEFs induce a histological response linked to cell death and cytotoxic T-lymphocytes in an immunocompetent mouse model of peritoneal metastasis.

Authors:  A Taibi; M-L Perrin; J Albouys; J Jacques; C Yardin; S Durand-Fontanier; S M Bardet
Journal:  Clin Transl Oncol       Date:  2021-03-07       Impact factor: 3.405

3.  Reduction of muscle contraction and pain in electroporation-based treatments: An overview.

Authors:  Roberta Fusco; Elio Di Bernardo; Valeria D'Alessio; Simona Salati; Matteo Cadossi
Journal:  World J Clin Oncol       Date:  2021-05-24

4.  Electrochemotherapy Using Doxorubicin and Nanosecond Electric Field Pulses: A Pilot in Vivo Study.

Authors:  Vitalij Novickij; Veronika Malyško; Augustinas Želvys; Austėja Balevičiūtė; Auksė Zinkevičienė; Jurij Novickij; Irutė Girkontaitė
Journal:  Molecules       Date:  2020-10-09       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.