Lateralized Periodic Discharges Frequency Correlates With Glucose Metabolism Subramaniam T, Jain A, Hall LT, Cole AJ, Westover MB, Rosenthal ES, Struck AF. Neurology. 2019;92(7):e670-e674. OBJECTIVE: To investigate the correlation between characteristics of lateralized periodic discharges (LPDs) and glucose metabolism measured by (18)F-fluorodeoxyglucose (FDG)-positron emission tomography (PET). METHODS: We retrospectively reviewed medical records to identify patients who underwent FDG-PET during electroencephalography (EEG) monitoring with LPDs present during the FDG uptake period. Two blinded board-certified neurophysiologists independently interpreted EEGs. (18)F-fluorodeoxyglucose uptake was measured using standardized uptake value (SUV). Structural images were fused with PET images to aid with localization of SUV. Two PET readers independently measured maximum SUV. Relative SUV values were obtained by normalization of the maximum SUV to the SUV of pons (SUVRpons). Lateralized periodic discharge frequency was analyzed both as a categorical variable and as a continuous measure. Other secondary variables included duration, amplitude, presence of structural lesion, and "plus" EEG features such as rhythmic or fast sharp activity. RESULTS: Nine patients were identified and 7 had a structural etiology for LPDs. Analysis using frequency as a categorical variable and continuous variable showed an association between increased LPD frequency and increased ipsilateral SUVRpons (P = .02). Metabolism associated with LPDs (0.5 Hz as a baseline) increased by a median of 100% at 1 Hz and for frequencies >1 Hz increased by a median of 309%. There were no statistically significant differences in SUVRpons for other factors including duration (P = .10), amplitude (P = .80), structural etiology (P = .55), or "plus" features such as rhythmic or fast sharp activity (P = .84). CONCLUSIONS: Metabolic activity increases monotonically with LPD frequency. Lateralized periodic discharge frequency should be a measure of interest when developing neuroprotection strategies in critical neurologic illness. Continuous Electroencephalography After Moderate to Severe Traumatic Brain Injury Lee H, Mizrahi MA, Hartings JA, Sharma S, Pahren L, Ngwenya LB, Moseley BD, Privitera M, Tortella FC, Foreman B. Crit Care Med. 2019;47(4):574-582. OBJECTIVES: After traumatic brain injury, continuous electroencephalography is widely used to detect electrographic seizures. With the development of standardized continuous electroencephalography terminology, we aimed to describe the prevalence and burden of ictal-interictal patterns, including electrographic seizures after moderate to severe traumatic brain injury, and to correlate continuous electroencephalography features with functional outcome. DESIGN: Post hoc analysis of the prospective, randomized controlled phase 2 multicenter INTREPID study ( ClinicalTrials.gov : NCT00805818). Continuous electroencephalography was initiated upon admission to the intensive care unit. The primary outcome was the 3-month Glasgow Outcome Scale-Extended. Consensus electroencephalography reviews were performed by raters certified in standardized continuous electroencephalography terminology blinded to clinical data. Rhythmic, periodic, or ictal patterns were referred to as "ictal-interictal continuum"; severe ictal-interictal continuum was defined as greater than or equal to 1.5 Hz lateralized rhythmic delta activity or generalized periodic discharges and any lateralized periodic discharges or electrographic seizures. SETTING: Twenty US level I trauma centers. PATIENTS: Patients with nonpenetrating traumatic brain injury and postresuscitation Glasgow Coma Scale score of 4 to 12 were included. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among 152 patients with continuous electroencephalography (age = 34 ± 14 years; 88% male), 22 (14%) had severe ictal-interictal continuum including electrographic seizures in 4 (2.6%). Severe ictal-interictal continuum burden correlated with initial prognostic scores, including the International Mission for Prognosis and Analysis of Clinical Trials in Traumatic Brain Injury (r = 0.51; P = .01) and Injury Severity Score (r = 0.49; P = .01), but not with functional outcome. After controlling clinical covariates, unfavorable outcome was independently associated with absence of posterior dominant rhythm (common odds ratio, 3.38; 95% confidence interval, 1.30-9.09), absence of N2 sleep transients (3.69; 1.69-8.20), predominant delta activity (2.82; 1.32-6.10), and discontinuous background (5.33; 2.28-12.96) within the first 72 hours of monitoring. CONCLUSIONS: Severe ictal-interictal continuum patterns, including electrographic seizures, were associated with clinical markers of injury severity but not functional outcome in this prospective cohort of patients with moderate to severe traumatic brain injury. Importantly, continuous electroencephalography background features were independently associated with functional outcome and improved the area under the curve of existing, validated predictive models.
Lateralized Periodic Discharges Frequency Correlates With Glucose Metabolism Subramaniam T, Jain A, Hall LT, Cole AJ, Westover MB, Rosenthal ES, Struck AF. Neurology. 2019;92(7):e670-e674. OBJECTIVE: To investigate the correlation between characteristics of lateralized periodic discharges (LPDs) and glucose metabolism measured by (18)F-fluorodeoxyglucose (FDG)-positron emission tomography (PET). METHODS: We retrospectively reviewed medical records to identify patients who underwent FDG-PET during electroencephalography (EEG) monitoring with LPDs present during the FDG uptake period. Two blinded board-certified neurophysiologists independently interpreted EEGs. (18)F-fluorodeoxyglucose uptake was measured using standardized uptake value (SUV). Structural images were fused with PET images to aid with localization of SUV. Two PET readers independently measured maximum SUV. Relative SUV values were obtained by normalization of the maximum SUV to the SUV of pons (SUVRpons). Lateralized periodic discharge frequency was analyzed both as a categorical variable and as a continuous measure. Other secondary variables included duration, amplitude, presence of structural lesion, and "plus" EEG features such as rhythmic or fast sharp activity. RESULTS: Nine patients were identified and 7 had a structural etiology for LPDs. Analysis using frequency as a categorical variable and continuous variable showed an association between increased LPD frequency and increased ipsilateral SUVRpons (P = .02). Metabolism associated with LPDs (0.5 Hz as a baseline) increased by a median of 100% at 1 Hz and for frequencies >1 Hz increased by a median of 309%. There were no statistically significant differences in SUVRpons for other factors including duration (P = .10), amplitude (P = .80), structural etiology (P = .55), or "plus" features such as rhythmic or fast sharp activity (P = .84). CONCLUSIONS: Metabolic activity increases monotonically with LPD frequency. Lateralized periodic discharge frequency should be a measure of interest when developing neuroprotection strategies in critical neurologic illness. Continuous Electroencephalography After Moderate to Severe Traumatic Brain Injury Lee H, Mizrahi MA, Hartings JA, Sharma S, Pahren L, Ngwenya LB, Moseley BD, Privitera M, Tortella FC, Foreman B. Crit Care Med. 2019;47(4):574-582. OBJECTIVES: After traumatic brain injury, continuous electroencephalography is widely used to detect electrographic seizures. With the development of standardized continuous electroencephalography terminology, we aimed to describe the prevalence and burden of ictal-interictal patterns, including electrographic seizures after moderate to severe traumatic brain injury, and to correlate continuous electroencephalography features with functional outcome. DESIGN: Post hoc analysis of the prospective, randomized controlled phase 2 multicenter INTREPID study ( ClinicalTrials.gov : NCT00805818). Continuous electroencephalography was initiated upon admission to the intensive care unit. The primary outcome was the 3-month Glasgow Outcome Scale-Extended. Consensus electroencephalography reviews were performed by raters certified in standardized continuous electroencephalography terminology blinded to clinical data. Rhythmic, periodic, or ictal patterns were referred to as "ictal-interictal continuum"; severe ictal-interictal continuum was defined as greater than or equal to 1.5 Hz lateralized rhythmic delta activity or generalized periodic discharges and any lateralized periodic discharges or electrographic seizures. SETTING: Twenty US level I trauma centers. PATIENTS: Patients with nonpenetrating traumatic brain injury and postresuscitation Glasgow Coma Scale score of 4 to 12 were included. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among 152 patients with continuous electroencephalography (age = 34 ± 14 years; 88% male), 22 (14%) had severe ictal-interictal continuum including electrographic seizures in 4 (2.6%). Severe ictal-interictal continuum burden correlated with initial prognostic scores, including the International Mission for Prognosis and Analysis of Clinical Trials in Traumatic Brain Injury (r = 0.51; P = .01) and Injury Severity Score (r = 0.49; P = .01), but not with functional outcome. After controlling clinical covariates, unfavorable outcome was independently associated with absence of posterior dominant rhythm (common odds ratio, 3.38; 95% confidence interval, 1.30-9.09), absence of N2 sleep transients (3.69; 1.69-8.20), predominant delta activity (2.82; 1.32-6.10), and discontinuous background (5.33; 2.28-12.96) within the first 72 hours of monitoring. CONCLUSIONS: Severe ictal-interictal continuum patterns, including electrographic seizures, were associated with clinical markers of injury severity but not functional outcome in this prospective cohort of patients with moderate to severe traumatic brain injury. Importantly, continuous electroencephalography background features were independently associated with functional outcome and improved the area under the curve of existing, validated predictive models.
Lateralized Periodic Discharges Frequency Correlates With Glucose
MetabolismSubramaniam T, Jain A, Hall LT, Cole AJ, Westover MB, Rosenthal ES,
Struck AF. Neurology. 2019;92(7):e670-e674.
Objective:
To investigate the correlation between characteristics of lateralized
periodic discharges (LPDs) and glucose metabolism measured by
(18)F-fluorodeoxyglucose (FDG)-positron emission tomography
(PET).
Methods:
We retrospectively reviewed medical records to identify patients who
underwent FDG-PET during electroencephalography (EEG) monitoring
with LPDs present during the FDG uptake period. Two blinded
board-certified neurophysiologists independently interpreted EEGs.
(18)F-fluorodeoxyglucose uptake was measured using standardized
uptake value (SUV). Structural images were fused with PET images to
aid with localization of SUV. Two PET readers independently measured
maximum SUV. Relative SUV values were obtained by normalization of
the maximum SUV to the SUV of pons (SUVRpons). Lateralized periodic
discharge frequency was analyzed both as a categorical variable and
as a continuous measure. Other secondary variables included
duration, amplitude, presence of structural lesion, and “plus” EEG
features such as rhythmic or fast sharp activity.
Results:
Nine patients were identified and 7 had a structural etiology for
LPDs. Analysis using frequency as a categorical variable and
continuous variable showed an association between increased LPD
frequency and increased ipsilateral SUVRpons (P =
.02). Metabolism associated with LPDs (0.5 Hz as a baseline)
increased by a median of 100% at 1 Hz and for frequencies >1 Hz
increased by a median of 309%. There were no statistically
significant differences in SUVRpons for other factors including
duration (P = .10), amplitude (P =
.80), structural etiology (P = .55), or “plus”
features such as rhythmic or fast sharp activity (P
= .84).
Conclusions:
Metabolic activity increases monotonically with LPD frequency.
Lateralized periodic discharge frequency should be a measure of
interest when developing neuroprotection strategies in critical
neurologic illness.Continuous Electroencephalography After Moderate to Severe
Traumatic Brain InjuryLee H, Mizrahi MA, Hartings JA, Sharma S, Pahren L, Ngwenya LB,
Moseley BD, Privitera M, Tortella FC, Foreman B. Crit Care
Med. 2019;47(4):574-582.
Objectives:
After traumatic brain injury, continuous electroencephalography is
widely used to detect electrographic seizures. With the development
of standardized continuous electroencephalography terminology, we
aimed to describe the prevalence and burden of ictal–interictal
patterns, including electrographic seizures after moderate to severe
traumatic brain injury, and to correlate continuous
electroencephalography features with functional outcome.
Design:
Post hoc analysis of the prospective, randomized controlled phase 2
multicenter INTREPID study (ClinicalTrials.gov: NCT00805818). Continuous
electroencephalography was initiated upon admission to the intensive
care unit. The primary outcome was the 3-month Glasgow Outcome
Scale–Extended. Consensus electroencephalography reviews were
performed by raters certified in standardized continuous
electroencephalography terminology blinded to clinical data.
Rhythmic, periodic, or ictal patterns were referred to as
“ictal–interictal continuum”; severe ictal–interictal continuum was
defined as greater than or equal to 1.5 Hz lateralized rhythmic
delta activity or generalized periodic discharges and any
lateralized periodic discharges or electrographic seizures.
Setting:
Twenty US level I trauma centers. PATIENTS: Patients with
nonpenetrating traumatic brain injury and postresuscitation Glasgow
Coma Scale score of 4 to 12 were included.
Interventions:
None.
Measurements and main results:
Among 152 patients with continuous electroencephalography (age = 34 ±
14 years; 88% male), 22 (14%) had severe ictal–interictal continuum
including electrographic seizures in 4 (2.6%). Severe
ictal–interictal continuum burden correlated with initial prognostic
scores, including the International Mission for Prognosis and
Analysis of Clinical Trials in Traumatic Brain Injury
(r = 0.51; P = .01) and Injury
Severity Score (r = 0.49; P =
.01), but not with functional outcome. After controlling clinical
covariates, unfavorable outcome was independently associated with
absence of posterior dominant rhythm (common odds ratio, 3.38; 95%
confidence interval, 1.30-9.09), absence of N2 sleep transients
(3.69; 1.69-8.20), predominant delta activity (2.82; 1.32-6.10), and
discontinuous background (5.33; 2.28-12.96) within the first 72
hours of monitoring.Severe ictal–interictal continuum patterns, including electrographic
seizures, were associated with clinical markers of injury severity
but not functional outcome in this prospective cohort of patients
with moderate to severe traumatic brain injury. Importantly,
continuous electroencephalography background features were
independently associated with functional outcome and improved the
area under the curve of existing, validated predictive models.
Commentary
The ictal–interictal continuum (IIC) encompasses electroencephalography (EEG)
patterns that neither meet the criteria for seizures nor are purely interictal.
There is general agreement that these include rhythmic or periodic discharges
between 1 and 2.5 Hz, particularly those that are ictal appearing or with
fluctuating frequency patterns. The more destructive of these, periodic discharges,
have been described for over 50 years. They range from the highly destructive ictal,
in a continuum to the relatively benign interictal without implication for ongoing
brain injury.[1] There is still a lack of consensus regarding the optimal approach to treating
them. Periodic discharges confined to a single hemisphere and referred to
historically as periodic lateralized epileptiform discharges or more recently as
lateralized periodic discharges (LPDs)[2] have the highest association with clinical and electrographic seizures.[3] Certain morphological characteristics[4] and increasing frequencies of these discharges increase the strength of this association.[3]Recent standardization of the electrographic characterization of these periodic
discharges through the American Clinical Neurophysiology Society’s Standardized
Critical Care EEG Terminology has allowed for more systematic studies of these patterns.[2] Of particular interest is whether these discharges, occupying what is
described as the IIC,[5] are independently associated with poor clinical outcome.Several previous studies provide clues to the possible mechanisms tying these
patterns to brain injury. In a study utilizing intracranial EEGs and microdialysis
of patients with traumatic brain injury (TBI), periodic discharges were associated
with elevated lactate/pyruvate ratios, suggesting a “metabolic crisis,” predominated
by impaired oxidative metabolism,[6] presumably due to increased metabolic demand that outstrips supply. Multiple
studies have demonstrated that LPDs are associated with increased metabolism as
demonstrated by increased glucose utilization on fluorodeoxyglucose positron
emission tomography (PET). The lack of clinical symptoms with some of these LPDs has
suggested that they may represent relatively benign phenomena. However, at least one
study has implied that the anatomical location at an eloquent cortical region is in
fact what differentiates symptomatic from asymptomatic LPDs.[7]Two recent studies both illuminate and blur what we know—or thought we knew—regarding
the patterns of the IIC. Subramaniam et al build on the concept of the link between
LPDs and hypermetabolism by providing evidence of a robust dose response between the
frequency of the discharges and degree of hypermetabolism. In a small retrospective
study, they analyzed all patients with LPDs on continuous EEG monitoring who
underwent a PET scan. Lateralized periodic discharge frequency was associated with
metabolic activity in the same hemisphere, though not necessarily strictly in a
superficial cortical region. Patients with LPDs discharging at 1 Hz and >1 Hz had
FDG update that was 100% and 309% higher, respectively, than patients whose LPDs
discharged at <1 Hz. The inference is that LPDs (particularly, presumably, with
higher frequencies) should be more aggressively treated.The strength of the study is that within their population, the effect size is
substantial and, despite their small sample size, is quite convincing. There are
several problems with this study that limit its generalizability. Firstly, the
sample size is truly small, consisting of a total of 9 patients. As a retrospective
study, it is virtually guaranteed that there was selection bias. Patients who
underwent continuous EEG likely underwent PET scans because of suspicion that the
LPDs were potentially highly epileptiform. Even a single patient whose study did not
conform to the expected association between LPD frequency and increased metabolism
may have resulted in nonsignificance of their main results. It is not stated at
which time point of the patient’s admission, in relation to the EEG, the PET scan
was obtained, thus making the relationship between the 2 parameters more tenuous.
The choice of parameters, while convenient for this population, does not necessarily
examine the frequency changes of greatest interest, as other studies have suggested
that an increase in risk of both seizures and potential hypoxic injury occurs at
frequencies above 1.5 to 2 Hz.[3,8] There are certainly examples in the literature where LPDs at ∼1 Hz are
associated with clear hypometabolism,[9] thus raising the likelihood that the underlying pathophysiology of LPDs is
heterogeneous, and do not necessarily result in the final pathway of increasing
tissue metabolism, and by extension, ischemia, inflammation, or other features of
the “metabolic crisis.”Nonetheless, within these significant limitations, it would seem reasonable that
patients with LPDs with higher frequency discharges should raise alarm. The hope is
that a change in intervention would result in an improvement in clinical outcome.
However, in this respect, definitive evidence remains elusive.Lee et al report a post hoc analysis of a large multicenter study of 155 patients
with moderate to severe TBI who also obtained continuous EEG monitoring. Their goal
was to determine what continuous EEG features were predictive of long-term
functional outcome. Ictal–interictal continuum patterns were categorized as severe
versus nonsevere, and the burden of the IIC was estimated by the frequency of the
IIC pattern multiplied by its duration. Approximately half of patients had patterns
that were consistent with IIC, and about 15% had severe IIC. Outcome was evaluated
at 3 months by the Glasgow Outcome Scale–Extended. The severity of the IIC was
associated with the TBI severity measure. However, although functional outcome was
associated with characteristics of EEG baseline and the presence of stage 2 sleep,
it was not associated with either the severity or burden of IIC patterns.This is the largest, most comprehensive study of patients with TBI and continuous
EEG, correcting for known determinants of functional outcome; the results appear
quite robust. The evaluation of both background and IIC on EEG was performed using
standardized terminology. The fact that only approximately 60% of patients in this
cohort obtained EEGs again leads to questions of selection bias, and indeed, the
patients with more TBI were more likely to have obtained cEEG. If all patients were
included, a significant univariate association with IIC may have been detected,
though it is still doubtful whether it would have remained significant after
accounting for other background cEEG features. It is also possible that cognitive
changes more subtle than can be evaluated by their measure of functional outcome are
associated.Although no association between IIC patterns and functional outcome was found in this
study, it is important to recall that this relationship has been demonstrated in
other conditions such as subarachnoid hemorrhage[10]—though again, this has not been universally replicated.[11] Clearly more research is needed in determining the effect of IIC patterns.
What is apparent, though, is that the mechanisms that produce IIC patterns are
heterogeneous, and their effects likely dependent on the underlying neurological
insult. Unfortunately, this does not allow treatment to be organized into simple
principles based on data, and a large degree of individualized patient management
algorithms may be necessary, as evidenced by several recent helpful guides.[12-14]
Authors: Jan Claassen; Lawrence J Hirsch; Jennifer A Frontera; Andres Fernandez; Michael Schmidt; Gregory Kapinos; John Wittman; E Sander Connolly; Ronald G Emerson; Stephan A Mayer Journal: Neurocrit Care Date: 2006 Impact factor: 3.210
Authors: L J Hirsch; S M LaRoche; N Gaspard; E Gerard; A Svoronos; S T Herman; R Mani; H Arif; N Jette; Y Minazad; J F Kerrigan; P Vespa; S Hantus; J Claassen; G B Young; E So; P W Kaplan; M R Nuwer; N B Fountain; F W Drislane Journal: J Clin Neurophysiol Date: 2013-02 Impact factor: 2.177
Authors: Indranil Sen-Gupta; Stephan U Schuele; Micheal P Macken; Mary J Kwasny; Elizabeth E Gerard Journal: Epilepsy Behav Date: 2014-06-13 Impact factor: 2.937
Authors: Paul Vespa; Meral Tubi; Jan Claassen; Manuel Buitrago-Blanco; David McArthur; Angela G Velazquez; Bin Tu; Mayumi Prins; Marc Nuwer Journal: Ann Neurol Date: 2016-02-28 Impact factor: 10.422