Literature DB >> 3119561

Evaluation of penicylinders used in disinfectant testing: bacterial attachment and surface texture.

E C Cole1, W A Rutala, J L Carson.   

Abstract

Two possible deficiencies in the AOAC use-dilution method for registration of chemical disinfectants by the Environmental Protection Agency are examined: (1) the physical disparities among brands of penicylinders and (2) the variability of bacterial numbers on penicylinders depending upon test strain and penicylinder surface texture. Textural differences of 2 brands of stainless steel penicylinders, one brand of porcelain, and one brand of glass were assessed by scanning electron microscopy. A considerable variation in smoothness of both inner and outer surfaces of stainless steel and porcelain penicylinders was observed. Glass penicylinders were very smooth. Numbers of bacteria attached to a penicylinder were assessed by vortexing the penicylinders 30 s at No. 4 after using the AOAC method of bacterial inoculation and drying 40 min at 37 degrees C. With this methodology, stainless steel carriers retained the 3 AOAC-recommended bacterial test strains differentially: ca 10(7) for Pseudomonas aeruginosa, 5 X 10(6) for Staphylococcus aureus, and 10(6) for Salmonella choleraesuis; glass retained 10(6)-10(7) organisms of all 3 test strains; porcelain retained about that amount of S. aureus but 10(5)-10(6) P. aeruginosa and 10(3)-10(4) S. choleraesuis. These data suggest that disinfectants are not similarly challenged with the AOAC-recommended test bacteria and that an alternative method should be considered to ensure comparable numbers of bacteria on penicylinders.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3119561

Source DB:  PubMed          Journal:  J Assoc Off Anal Chem        ISSN: 0004-5756


  3 in total

1.  Effect of methodology, dilution, and exposure time on the tuberculocidal activity of glutaraldehyde-based disinfectants.

Authors:  E C Cole; W A Rutala; L Nessen; N S Wannamaker; D J Weber
Journal:  Appl Environ Microbiol       Date:  1990-06       Impact factor: 4.792

2.  Comparative mycobactericidal efficacy of chemical disinfectants in suspension and carrier tests.

Authors:  M Best; S A Sattar; V S Springthorpe; M E Kennedy
Journal:  Appl Environ Microbiol       Date:  1988-11       Impact factor: 4.792

3.  Pseudomonas pellicle in disinfectant testing: electron microscopy, pellicle removal, and effect on test results.

Authors:  E C Cole; W A Rutala; J L Carson; E M Alfano
Journal:  Appl Environ Microbiol       Date:  1989-02       Impact factor: 4.792

  3 in total