Literature DB >> 31195199

A Portable Device for Rapid Detection of Human Serum Albumin using an immunoglobulin-coating-based Magnetoelastic Biosensor.

Shengbo Sang1, Yuchao Li1, Xing Guo1, Bo Zhang1, Xianwei Xue1, Kai Zhuo1, Chun Zhao2, Wendong Zhang1, Zhongyun Yuan3.   

Abstract

Abnormal protein concentration levels in human body fluids, such as urine, serum etc., are considered to associate with disease states, providing essential information for the pre-clinical diagnosis. This paper presents a wireless immunoglobulin-coated magnetoelastic (ME) biosensor for fast, cost-effective detections of human serum albumin (HSA) with small sample volumes at a microliter scale. This is the first portable resonant sensor based on magnetostrictive effect that can monitor different molecular states of HSA. Anti-HSA Immunoglobulin G (IgG) was immobilized on the surface of the ME sensor to selectively capture HSA. The rapid conjugation between the antibody and antigen changed the sensor surface states and thus induced resonance frequency shifts (RFS), which were monitored in real time for the qualitative and quantitative analysis of HSA. This paper brings forward a System on Chip (SoC)-based system architecture to realize the function of RFS sampling. The performance of the portable device was validated to be comparable to that of the Vector Network Analyzer (VNA) AV3620 using different concentrations of HSA solution. The RFS were linearly proportional to the HSA concentrations in the range from 0.1 to 100 μg/mL with a linearity up to 0.998, a sensitivity of 8.70 Hz/μg.mL-1 and a detection limit of 0.039 μg/mL, indicating good feasibility of this method. Meanwhile, the response of this portable ME biosensor was quick and specific to HSA targets. This ME biosensor shows high potential to be used in diagnosing abnormal HSA.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anti-HSA immunoglobulin G (IgG); Human serum albumin (HSA); Magnetoelastic (ME) biosensor; Portable device; Resonance frequency shift (RFS)

Mesh:

Substances:

Year:  2019        PMID: 31195199     DOI: 10.1016/j.bios.2019.111399

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

1.  A Novel NiFe2O4/Paper-Based Magnetoelastic Biosensor to Detect Human Serum Albumin.

Authors:  Xing Guo; Rong Liu; Hongmei Li; Jingzhe Wang; Zhongyun Yuan; Wendong Zhang; Shengbo Sang
Journal:  Sensors (Basel)       Date:  2020-09-16       Impact factor: 3.576

2.  Impedimetric Sensing of Factor V Leiden Mutation by Zip Nucleic Acid Probe and Electrochemical Array.

Authors:  Arzum Erdem; Ece Eksin
Journal:  Biosensors (Basel)       Date:  2020-09-07

Review 3.  A Review of Piezoelectric and Magnetostrictive Biosensor Materials for Detection of COVID-19 and Other Viruses.

Authors:  Fumio Narita; Zhenjin Wang; Hiroki Kurita; Zhen Li; Yu Shi; Yu Jia; Constantinos Soutis
Journal:  Adv Mater       Date:  2020-11-24       Impact factor: 32.086

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.