Recommendations for laboratory informatics specifications needed for the application of patient-based real time quality control.

Tze Ping Loh1, Mark A Cervinski2, Alex Katayev3, Andreas Bietenbeck4, Huub van Rossum5, Tony Badrick6.   

Abstract

Patient based real time Quality Control (PBRTQC) algorithms provide many advantages over conventional QC approaches including lower cost, absence of commutability problems, continuous real-time monitoring of performance, and sensitivity to pre-analytical error. However, PBRTQC is not as simple to implement as conventional QC because of the requirement to access patient data as well as setting up appropriate rules, action protocols, and choosing best statistical algorithms. These requirements need capable and flexible laboratory informatics (middleware). In this document, the necessary features of software packages needed to support PBRTQC are discussed as well as recommendations for optimal integration of this technique into laboratory practice.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Data mining; Middleware; Moving averages; Patient based real time quality control

Mesh:

Year:  2019        PMID: 31194967     DOI: 10.1016/j.cca.2019.06.009

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  4 in total

1.  Patient-based quality control for glucometers: using the moving sum of positive patient results and moving average.

Authors:  Chun Yee Lim; Tony Badrick; Tze Ping Loh
Journal:  Biochem Med (Zagreb)       Date:  2020-06-15       Impact factor: 2.313

2.  Impact of combining data from multiple instruments on performance of patient-based real-time quality control.

Authors:  Qianqian Zhou; Tze Ping Loh; Tony Badrick; Chun Yee Lim
Journal:  Biochem Med (Zagreb)       Date:  2021-04-15       Impact factor: 2.313

3.  Moving average procedures as an additional tool for real-time analytical quality control: challenges and opportunities of implementation in small-volume medical laboratories.

Authors:  Vera Lukić; Svetlana Ignjatović
Journal:  Biochem Med (Zagreb)       Date:  2021-12-15       Impact factor: 2.313

4.  Comparison and optimization of various moving patient-based real-time quality control procedures for serum sodium.

Authors:  Yuanyuan Li; Qian Yu; Xiaoyan Zhang; Xiaoling Chen
Journal:  J Clin Lab Anal       Date:  2021-09-14       Impact factor: 2.352