Literature DB >> 31191091

Non-Uniformity of Elbow Flexors Damage Induced by an Eccentric Protocol in Untrained Men.

Thiago T Matta1,2, Raphael O Pinto1, Bruno F M Leitão1, Liliam F Oliveira1,2.   

Abstract

Muscle structure disorganization is a consequence of intense eccentric contractions, with symptoms that characterize exercise-induced muscle damage (EIMD). To date, few studies have described EIMD parameters at different muscle sites. The aim of the present study was to analyse indirect markers of EIMD at two elbow flexors sites over three days. Eleven healthy untrained men were submitted to a session of three sets of 10 eccentric elbow flexion repetitions on an isokinetic dynamometer. The isometric peak torque (PT), muscle soreness, elbow flexors oedema, (normalized muscle thickness [MT]) and echo-intensity (EI) were measured. There was a significant decrease in PT immediately after (Post) and 10 min, 24 h, 48 h and 72 h after intervention compared to that at baseline (p < 0 .05). MT% increased after 72 h compared with that immediately, 10 min and 24 h after intervention (p < 0.05). No statistical changes were observed in muscle soreness and oedema between the two muscle sites. With respect to EI%, significant differences were observed for the 24 h, 48 h and 72 h measures compared with those of the Post, 10 min and 24 h measures for both muscle sites; at the distal site, EI% was significantly higher than at the proximal site for measures after 24 h (p < 0.05). The presence of differences in EI% 24 h after eccentric training on distal sites of elbow flexors indicates non-uniform EIMD in this region.

Entities:  

Keywords:  Eccentric contractions; echo intensity; muscle soreness; resistance training; ultrasound

Mesh:

Year:  2019        PMID: 31191091      PMCID: PMC6543989     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  25 in total

Review 1.  What mechanisms contribute to the strength loss that occurs during and in the recovery from skeletal muscle injury?

Authors:  Gordon L Warren; Christopher P Ingalls; Dawn A Lowe; R B Armstrong
Journal:  J Orthop Sports Phys Ther       Date:  2002-02       Impact factor: 4.751

2.  Effects of a second bout of maximal eccentric exercise on muscle damage and electromyographic activity.

Authors:  Trevor C Chen
Journal:  Eur J Appl Physiol       Date:  2003-03-04       Impact factor: 3.078

3.  Effects of set-repetition configuration in eccentric exercise on muscle damage and the repeated bout effect.

Authors:  R Chan; M Newton; K Nosaka
Journal:  Eur J Appl Physiol       Date:  2011-11-19       Impact factor: 3.078

4.  Responses of elbow flexors to two strenuous eccentric exercise bouts separated by three days.

Authors:  Trevor C Chen; Kazunori Nosaka
Journal:  J Strength Cond Res       Date:  2006-02       Impact factor: 3.775

5.  Comparison between old and young men for responses to fast velocity maximal lengthening contractions of the elbow flexors.

Authors:  Dale W Chapman; M Newton; M R McGuigan; K Nosaka
Journal:  Eur J Appl Physiol       Date:  2008-06-27       Impact factor: 3.078

6.  Strength training's chronic effects on muscle architecture parameters of different arm sites.

Authors:  Thiago Matta; Roberto Simão; Belmiro Freitas de Salles; Juliano Spineti; Liliam Fernandes Oliveira
Journal:  J Strength Cond Res       Date:  2011-06       Impact factor: 3.775

7.  Effect of elbow joint angle on the magnitude of muscle damage to the elbow flexors.

Authors:  K Nosaka; K Sakamoto
Journal:  Med Sci Sports Exerc       Date:  2001-01       Impact factor: 5.411

Review 8.  Skeletal muscle ultrasound.

Authors:  Sigrid Pillen; Nens van Alfen
Journal:  Neurol Res       Date:  2011-12       Impact factor: 2.448

Review 9.  Measurement tools used in the study of eccentric contraction-induced injury.

Authors:  G L Warren; D A Lowe; R B Armstrong
Journal:  Sports Med       Date:  1999-01       Impact factor: 11.136

10.  Sensory and electromyographic mapping during delayed-onset muscle soreness.

Authors:  Nosratollah Hedayatpour; Deborah Falla; Lars Arendt-Nielsen; Dario Farina
Journal:  Med Sci Sports Exerc       Date:  2008-02       Impact factor: 5.411

View more
  2 in total

Review 1.  Echo intensity as an indicator of skeletal muscle quality: applications, methodology, and future directions.

Authors:  Matt S Stock; Brennan J Thompson
Journal:  Eur J Appl Physiol       Date:  2020-11-21       Impact factor: 3.078

2.  Changes in supramaximal M-wave amplitude at different regions of biceps brachii following eccentric exercise of the elbow flexors.

Authors:  Hélio V Cabral; Kristen M Meiburger; Liliam F de Oliveira; Taian M Vieira
Journal:  Eur J Appl Physiol       Date:  2020-10-17       Impact factor: 3.078

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.