Literature DB >> 31188273

Radiofrequency Coils for 7 Tesla MRI.

Oliver Kraff1, Harald H Quick1,2.   

Abstract

Radiofrequency (RF) coils are an essential part of the magnetic resonance (MR) system. To exploit the inherently higher signal-to-noise ratio at ultrahigh magnetic fields (UHF), research sites were forced to build up expertise in RF coil development, as the number of commercially available RF coils were limited. In addition, an integrated transmit body RF coil, which is well-established at MR systems of lower field strength, is still missing at UHF due to technical and physical constraints. This review article provides a brief recapitulation of RF characteristics and RF coils in general to introduce terminology and RF-related parameters, and will then provide an extensive overview of current state-of-the-art RF coils used for MRI from head to toe at 7 Tesla. Finally, a section on RF safety will briefly discuss challenges in performing a safety assessment for custom-designed RF coils, and issues arising from the interaction of the RF field and potentially implanted medical devices.

Mesh:

Year:  2019        PMID: 31188273     DOI: 10.1097/RMR.0000000000000206

Source DB:  PubMed          Journal:  Top Magn Reson Imaging        ISSN: 0899-3459


  5 in total

Review 1.  [Safety of implants in high field and ultrahigh field MRI].

Authors:  O Kraff; H H Quick
Journal:  Radiologe       Date:  2019-10       Impact factor: 0.635

2.  7T MR Thermometry technique for validation of system-predicted SAR with a home-built radiofrequency wrist coil.

Authors:  Andrew J Fagan; Paul S Jacobs; Thomas C Hulshizer; Phillip J Rossman; Matthew A Frick; Kimberly K Amrami; Joel P Felmlee
Journal:  Med Phys       Date:  2020-12-31       Impact factor: 4.071

3.  Ultra-High-Field MRI in the Diagnosis and Management of Gliomas: A Systematic Review.

Authors:  Annabelle Shaffer; Susanna S Kwok; Anant Naik; Aaron T Anderson; Fan Lam; Tracey Wszalek; Paul M Arnold; Wael Hassaneen
Journal:  Front Neurol       Date:  2022-04-05       Impact factor: 4.003

4.  7-T clinical MRI of the shoulder in patients with suspected lesions of the rotator cuff.

Authors:  Andrea Lazik-Palm; Oliver Kraff; Stefan H G Rietsch; Mark E Ladd; Michael Kamminga; Sascha Beck; Harald H Quick; Jens M Theysohn
Journal:  Eur Radiol Exp       Date:  2020-02-07

5.  Development and evaluation of a numerical simulation approach to predict metal artifacts from passive implants in MRI.

Authors:  Tobias Spronk; Oliver Kraff; Jakob Kreutner; Gregor Schaefers; Harald H Quick
Journal:  MAGMA       Date:  2021-10-16       Impact factor: 2.533

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.