Literature DB >> 311874

Iatrogenic coronary artery stenosis following aortic valve replacement.

G K Sethi, S M Scott, T Takaro.   

Abstract

Until recnetly, coronary arterial perfusion was one of the best methods to protect myocardium during aortic valve replacement. However, the insertion of perfusion cannulas may produce immediate traumatic lesions and late stenosis of the coronary arteries, with grave consequences. Two patients with normal coronary arteries prior to operation developed obstruction of the maximal left main coronary artery following aortic replacement. One of these patients represents the first case of iatrogenic coronary arterial stenosis in which the aortic valve was replaced with a porcine bioprosthesis. Accelerating angina pectoris and ventricular arrhythmias were the presenting clinical manifestations. Aorta-coronary bypass grafting to the left anterior descending and circumflex coronary arteries was successfully performed in one patient, while the other patient died before investigative procedures could be undertaken. Any patient whose aortic valve has been replaced and who develops angina pectoris a few months after operation should be suspected of having developed stenosis of the proximal coronary artery. Coronary angiography should be perfomed promptly. Once the lesion is recognized, the operaiton should be performed posthaste because these lesions are life threatening owing to their proximal location and rapid evolution.

Entities:  

Mesh:

Year:  1979        PMID: 311874

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  9 in total

1.  Coronary ostia obstruction after replacement of aortic valve prosthesis.

Authors:  Emanuela Turillazzi; Gabriele Di Giammarco; Margherita Neri; Stefania Bello; Irene Riezzo; Vittorio Fineschi
Journal:  Diagn Pathol       Date:  2011-08-02       Impact factor: 2.644

2.  Coronary ostial stenosis after aortic valve replacement: successful treatment of 2 patients with drug-eluting stents.

Authors:  Antonios G Ziakas; Fotios I Economou; Nicholas A Charokopos; Antonios A Pitsis; Despina G Parharidou; Thomas I Papadopoulos; Georgios E Parharidis
Journal:  Tex Heart Inst J       Date:  2010

3.  Acute Right Coronary Ostial Stenosis during Aortic Valve Replacement.

Authors:  Sarwar Umran; Govind Chetty; Pradip K Sarkar
Journal:  Int J Prev Med       Date:  2012-04

4.  Iatrogenic left anterior descending artery stenosis early after aortic valve replacement presenting with T-wave-pseudonormalization - a case report.

Authors:  Stefan Schwarz; Hermann Blessberger; Jürgen Kammler; Christoph Gross; Clemens Steinwender
Journal:  J Cardiothorac Surg       Date:  2015-03-21       Impact factor: 1.637

5.  Left Main Coronary Ostial Stenosis after Aortic Valve Replacement: A Case Report.

Authors:  Munish Sharma; Daniel Mascarenhas
Journal:  Clin Med Insights Case Rep       Date:  2016-11-28

6.  Delayed Development of Coronary Ostial Stenosis following Surgical Aortic Valve Replacement: A Case Report of Unusual Presentation.

Authors:  Doosup Shin; Kevin Huang; Igor Sunjic; Michael Berlowitz; Xavier Prida
Journal:  Case Rep Cardiol       Date:  2018-04-01

7.  Unstable angina early after aortic valve replacement surgery in a female patient with normal coronary arteries preoperatively--a case report.

Authors:  Sybille Gruber; Choi-Keung Ng; Christian Schwarz; Johann Auer
Journal:  J Cardiothorac Surg       Date:  2009-07-02       Impact factor: 1.637

8.  Acute coronary syndrome as a result of left main coronary artery stenosis after aortic valve replacement. A report of three cases.

Authors:  Aleksander Araszkiewicz; Maciej Lesiak; Tomasz Urbanowicz; Stanisław Jankiewicz; Stefan Grajek
Journal:  Postepy Kardiol Interwencyjnej       Date:  2013-06-17       Impact factor: 1.426

9.  Coronary ostial stenosis detected by transesophageal echocardiography after aortic valve replacement: a case report.

Authors:  Naomi Ono; Toshiyuki Sawai; Hisanari Ishii
Journal:  JA Clin Rep       Date:  2017-04-11
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.