Literature DB >> 31183933

Steerable Microinvasive Probes for Localized Drug Delivery to Deep Tissue.

Max J Cotler1,2, Erin B Rousseau1,2, Khalil B Ramadi1,2, Joshua Fang1, Ann M Graybiel3, Robert Langer1,2,4, Michael J Cima1,5.   

Abstract

Enhanced understanding of neuropathologies has created a need for more advanced tools. Current neural implants result in extensive glial scarring and are not able to highly localize drug delivery due to their size. Smaller implants reduce surgical trauma and improve spatial resolution, but such a reduction requires improvements in device design to enable accurate and chronic implantation in subcortical structures. Flexible needle steering techniques offer improved control over implant placement, but often require complex closed-loop control for accurate implantation. This study reports the development of steerable microinvasive neural implants (S-MINIs) constructed from borosilicate capillaries (OD = 60 µm, ID = 20 µm) that do not require closed-loop guidance or guide tubes. S-MINIs reduce glial scarring 3.5-fold compared to prior implants. Bevel steered needles are utilized for open-loop targeting of deep-brain structures. This study demonstrates a sinusoidal relationship between implant bevel angle and the trajectory radius of curvature both in vitro and ex vivo. This relationship allows for bevel-tipped capillaries to be steered to a target with an average error of 0.23 mm ± 0.19 without closed-loop control. Polished microcapillaries present a new microinvasive tool for chronic, predictable targeting of pathophysiological structures without the need for closed-loop feedback and complex imaging.
© 2019 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  borosilicate; drug delivery; needle steering; neuroengineering

Mesh:

Year:  2019        PMID: 31183933     DOI: 10.1002/smll.201901459

Source DB:  PubMed          Journal:  Small        ISSN: 1613-6810            Impact factor:   13.281


  2 in total

1.  Modular robotic platform for precision neurosurgery with a bio-inspired needle: System overview and first in-vivo deployment.

Authors:  Riccardo Secoli; Eloise Matheson; Marlene Pinzi; Stefano Galvan; Abdulhamit Donder; Thomas Watts; Marco Riva; Davide Danilo Zani; Lorenzo Bello; Ferdinando Rodriguez Y Baena
Journal:  PLoS One       Date:  2022-10-19       Impact factor: 3.752

2.  Platform for micro-invasive membrane-free biochemical sampling of brain interstitial fluid.

Authors:  Ritu Raman; Erin B Rousseau; Michael Wade; Allison Tong; Max J Cotler; Jenevieve Kuang; Alejandro Aponte Lugo; Elizabeth Zhang; Ann M Graybiel; Forest M White; Robert Langer; Michael J Cima
Journal:  Sci Adv       Date:  2020-09-25       Impact factor: 14.136

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.