Literature DB >> 31177981

Short-Term Double Layer Mesh Stent Patency for Emergent or Elective Carotid Artery Stenting.

Evelien E de Vries1, Evert J Vonken2, L Jaap Kappelle3, Raechel J Toorop1, Gert J de Borst1.   

Abstract

Background and Purpose- Novel double layer micromesh stents have recently been introduced for treatment of patients with significant carotid stenosis. Strict evaluation of safety and patency of such novel devices is required both in elective and in emergency interventions. We report a single center experience with double layer mesh stents for carotid artery revascularization. Methods- Consecutive patients who underwent carotid artery stenting with a double layer mesh stent between June 2015 and September 2018 in our tertiary vascular referral center were included. Treatment indications were emergent carotid artery stenting for intracranial or extracranial carotid stenosis in patients undergoing intraarterial thrombectomy for acute ischemic stroke in the anterior circulation, or elective carotid artery stenting for significant symptomatic or asymptomatic stenosis. End points were postprocedural thrombotic stent occlusion and procedural stroke or death. Results- Fifty-four patients were included; 27 were treated for acute stroke with intracranial and extracranial (tandem) lesions and 27 for elective stenting. Follow-up imaging was available for 9/27 (33%) patients with acute stroke, and 19/27 (70%) electively treated patients. Five stent occlusions occurred, of which 2 were symptomatic with clinical deterioration within one day. Another patient deteriorated on postprocedural day one, but imaging of the carotids was not performed, and the stent turned out occluded on the 30-day duplex. All stent occlusions occurred in patients treated for acute stroke. Conclusions- This study suggests that occlusion of novel double layer mesh stents occurs in a considerable proportion of carotid artery stenting procedures performed in the emergency setting for acute stroke, with occlusion-related symptoms in half the cases. Future prospective studies should clarify the role of double layer mesh stents in this high-risk patient population.

Entities:  

Keywords:  angioplasty; carotid stenosis; death; stents; thrombectomy

Mesh:

Year:  2019        PMID: 31177981     DOI: 10.1161/STROKEAHA.118.024586

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  2 in total

1.  Emergency carotid artery revascularization using Casper-RX stent: A single-center experience.

Authors:  Yigit Ozpeynirci; Cristian Capatana; Johannes Rosskopf; Bernd L Schmitz; Gerhard F Hamann; Michael Braun
Journal:  Interv Neuroradiol       Date:  2020-02-11       Impact factor: 1.610

2.  Safety and Efficacy of Carotid Artery Stenting with the CGuard Double-layer Stent in Acute Ischemic Stroke.

Authors:  Tomas Klail; Christoph Kurmann; Johannes Kaesmacher; Adnan Mujanovic; Eike I Piechowiak; Tomas Dobrocky; Sara Pilgram-Pastor; Adrian Scutelnic; Mirjam R Heldner; Jan Gralla; Pasquale Mordasini
Journal:  Clin Neuroradiol       Date:  2022-09-07       Impact factor: 3.156

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.