Literature DB >> 31177406

Low-fluence Q-switched Nd:YAG 1064-nm laser versus Q-switched Nd:YAG 532-nm laser in the treatment of hyperpigmented lips: a prospective, randomized, controlled, evaluator-blinded trial.

Nattawan Limpjaroenviriyakul1, Natthachat Jurairattanaporn1, Nanticha Kamanamool2, Salinee Rojhirunsakool1, Silada Kanokrungsee1, Montree Udompataikul3.   

Abstract

Lip hyperpigmentation is an esthetic problem. Clinical data from controlled comparative studies is insufficient to support the efficacy of laser treatments for hyperpigmented lips. This study is aimed to compare the efficacy of low-fluence Q-switched Nd:YAG 1064-nm laser (LFQS 1064-nm) versus Q-switched Nd:YAG 532-nm laser (QS 532-nm) for the treatment of hyperpigmented lips. A randomized, controlled, evaluator-blinded study was conducted in thirty subjects. They were randomized into 2 groups. The first group was treated with five treatment sessions with a 2-week interval of LFQS 1064-nm laser while the second group was treated with a single session of QS 532-nm laser. The evaluation was conducted at baseline, 2 weeks of each post treatment, and 4 weeks after the last treatment session. The efficacy was assessed by melanin index, Methuen colored plate, photographic evaluation, pain score, patient's satisfaction, and patient's Dermatology Life Quality Index. The adverse effects were also recorded. All patients attained throughout the study protocol. The most frequent fluence applied was 2.4 J/cm2 (2.2-2.5 J/cm2) and 2.0 J/cm2 (1.7-2.4 J/cm2) in the LFQS 1064-nm group and QS 532-nm group, respectively. The results of the QS 532-nm group showed greater percentage of melanin index reduction and better average mean of photographic evaluation percentage changes from the baseline than the LFQS 1064-nm group (p < 0.001 and p < 0.001, respectively). The adverse effects were less likely to occur in the LFQS 1064-nm group. Few cases of scale, hypopigmentation, bleb formation, postinflammatory hyperpigmentation, and labial edema occurred only in the QS 532-nm group.

Entities:  

Keywords:  Hyperpigmented lips; Low-fluence Q-switched Nd:YAG 1064-nm; Melanin index; Q-switched Nd:YAG 532-nm

Mesh:

Year:  2019        PMID: 31177406     DOI: 10.1007/s10103-019-02814-4

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  3 in total

1.  Efficacy and Safety of Q-switched Double-frequency 532-nm Neodymium-doped Yttrium Aluminum Garnet Laser in the Treatment of Lip Hyperpigmentation: A Pilot Study.

Authors:  Mohammed Al-Haddab; Azhar Alali; Homaid Al-Otiabi
Journal:  J Clin Aesthet Dermatol       Date:  2021-07-01

2.  Effects of water cooling on laser-induced thermal damage in rat hepatectomy.

Authors:  Liyu Shan; Rongfeng Wang; Yue Wang; Huan Chen; Shasha Wei; Dinghui Dong; Yi Lv; Tao Ma
Journal:  Lasers Surg Med       Date:  2022-04-04

3.  Er,Cr:YSGG 2780 nm Laser Treatment of Lip Melanin Hyperpigmentation.

Authors:  Manaf Taher Agha; Pavel Polenik; Mawada Hassan
Journal:  Int J Dent       Date:  2021-07-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.