Literature DB >> 31176564

Ten- to Sixteen-Year Follow-Up of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: What Factors Affect Wear?

Amy Cheung1, Chun Hoi Yan2, Henry Fu1, Man Hong Cheung2, Ping Keung Chan1, Kwong Yuen Chiu2.   

Abstract

BACKGROUND: Increase in acetabular cup abduction in total hip arthroplasty (THA) using conventional polyethylene is associated with greater linear wear. Whether this relationship holds true for highly crosslinked liners, particularly with long-term follow-up, is still controversial. The effect of liner thickness on wear of highly cross-linked liners also remains to be clarified.This study sought to determine (1) the long-term clinical and radiological performance of highly cross-linked polyethylene in THA and (2) the effect of acetabular component positioning, polyethylene thickness, and patient demographics on wear.
METHODS: Ninety-three THAs using a 28-mm hip ball, single brand of highly cross-linked polyethylene liner, and cementless cup were performed in 87 patients. Clinical outcomes were evaluated using the Harris Hip Score and need for revision surgery. Linear and volumetric wear, presence of osteolysis, and cup abduction angle were assessed.
RESULTS: The mean age at operation was 51.4 years. The mean duration of follow-up was 12.7 years (10-16 years). Patients aged >50 years had higher rates of linear wear than those aged <50 years (P = .015). Positive correlation was found between cup abduction angle (P = .014) and cup version (P = .035) with a linear wear rate. Thinner liners (≤7 mm) had similar rates of linear and volumetric wear as thicker liners (≥8 mm) (P = .447).
CONCLUSION: This is the only study to demonstrate a positive significant relationship between cup abduction angle and version with linear wear rate in THA with at least 10 years of follow-up. Liner thickness was not found to affect wear rates.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  factors affecting wear; highly cross-linked polyethylene; long-term follow-up; total hip arthroplasty; wear

Mesh:

Substances:

Year:  2019        PMID: 31176564     DOI: 10.1016/j.arth.2019.04.041

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

1.  Anatomic Total Hip Component Position Is More Reproducible With the Direct Anterior Approach Using Intraoperative Fluoroscopy.

Authors:  J Ryan Martin; John L Masonis; J Bohannon Mason
Journal:  Arthroplast Today       Date:  2020-09-08

2.  Heterotopic Ossification in Orthopaedic and Trauma surgery: A Histopathological Ossification Score.

Authors:  M Ohlmeier; V Krenn; D M Thiesen; N A Sandiford; T Gehrke; M Citak
Journal:  Sci Rep       Date:  2019-12-05       Impact factor: 4.379

3.  Recent update on crosslinked polyethylene in total hip arthroplasty.

Authors:  Jean Langlois; Moussa Hamadouche
Journal:  SICOT J       Date:  2020-05-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.