Tara I-Hsin Chang1, Sai Liu1, Medha Airy2, Jingbo Niu2, Mintu P Turakhia3,4, Jennifer E Flythe5, Maria E Montez-Rath1, Wolfgang C Winkelmayer6. 1. Divisions of Nephrology and. 2. Section of Nephrology and Selzman Institute for Kidney Health, Baylor College of Medicine, Houston, Texas. 3. Cardiovascular Medicine, Stanford University, Stanford, California. 4. Division of Cardiovascular Medicine, Palo Alto Veterans Affairs Medical Center, Palo Alto, California; and. 5. Division of Nephrology and Hypertension, Department of Medicine, University of North Carolina (UNC) Kidney Center, UNC School of Medicine, Chapel Hill, North Carolina. 6. Section of Nephrology and Selzman Institute for Kidney Health, Baylor College of Medicine, Houston, Texas; Wolfgang.Winkelmayer@bcm.edu.
Abstract
BACKGROUND AND OBJECTIVES: We examined the association of predialysis systolic and diastolic BP and intradialytic hypotension with incident atrial fibrillation in older patients initiating hemodialysis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: We used the US Renal Data System linked to the records of a large dialysis provider to identify patients aged ≥67 years initiating hemodialysis between January 2006 and October 2011. We examined quarterly average predialysis systolic BP, diastolic BP, and proportion of sessions with intradialytic hypotension (i.e., nadir systolic BP <90 mm Hg). We applied an extended Cox model to compute adjusted hazard ratios (HRs) of each exposure with incident atrial fibrillation. RESULTS: Among 17,003 patients, 3785 developed atrial fibrillation. When comparing predialysis systolic BP to a fixed reference of 140 mm Hg, lower predialysis systolic BP was associated with a higher hazard of atrial fibrillation, whereas higher systolic BP was associated with a lower hazard of atrial fibrillation. When comparing across a range of systolic BP for two hypothetical patients with similar measured covariates, the association varied by mean systolic BP: at systolic BP 190 mm Hg, each 10 mm Hg lower systolic BP was associated with lower atrial fibrillation hazard (HR, 0.94; 95% confidence interval, 0.90 to 1.00), whereas at systolic BP 140 mm Hg, a 10 mm Hg lower systolic BP was associated with a higher atrial fibrillation hazard (HR, 1.12; 95% confidence interval, 1.10 to 1.14). Lower diastolic BP was associated with higher atrial fibrillation hazards. Intradialytic hypotension was weakly associated with atrial fibrillation. CONCLUSIONS: In this observational study of older patients initiating hemodialysis, lower predialysis systolic BP and diastolic BP were associated with higher incidence of atrial fibrillation.
BACKGROUND AND OBJECTIVES: We examined the association of predialysis systolic and diastolic BP and intradialytic hypotension with incident atrial fibrillation in older patients initiating hemodialysis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: We used the US Renal Data System linked to the records of a large dialysis provider to identify patients aged ≥67 years initiating hemodialysis between January 2006 and October 2011. We examined quarterly average predialysis systolic BP, diastolic BP, and proportion of sessions with intradialytic hypotension (i.e., nadir systolic BP <90 mm Hg). We applied an extended Cox model to compute adjusted hazard ratios (HRs) of each exposure with incident atrial fibrillation. RESULTS: Among 17,003 patients, 3785 developed atrial fibrillation. When comparing predialysis systolic BP to a fixed reference of 140 mm Hg, lower predialysis systolic BP was associated with a higher hazard of atrial fibrillation, whereas higher systolic BP was associated with a lower hazard of atrial fibrillation. When comparing across a range of systolic BP for two hypothetical patients with similar measured covariates, the association varied by mean systolic BP: at systolic BP 190 mm Hg, each 10 mm Hg lower systolic BP was associated with lower atrial fibrillation hazard (HR, 0.94; 95% confidence interval, 0.90 to 1.00), whereas at systolic BP 140 mm Hg, a 10 mm Hg lower systolic BP was associated with a higher atrial fibrillation hazard (HR, 1.12; 95% confidence interval, 1.10 to 1.14). Lower diastolic BP was associated with higher atrial fibrillation hazards. Intradialytic hypotension was weakly associated with atrial fibrillation. CONCLUSIONS: In this observational study of older patients initiating hemodialysis, lower predialysis systolic BP and diastolic BP were associated with higher incidence of atrial fibrillation.
Authors: Zhensheng Li; Eduardo Lacson; Edmund G Lowrie; Norma J Ofsthun; Martin K Kuhlmann; J Michael Lazarus; Nathan W Levin Journal: Am J Kidney Dis Date: 2006-10 Impact factor: 8.860
Authors: Gürkan Acar; Ahmet Akçay; Ekrem Doğan; Ismet Onder Işik; Abdullah Sökmen; Gülizar Sökmen; Hayriye Sayarlioğlu; Sedat Köroğlu; Alper Buğra Nacar; Cemal Tuncer Journal: Turk Kardiyol Dern Ars Date: 2010-01
Authors: James B Wetmore; Jonathan D Mahnken; Sally K Rigler; Edward F Ellerbeck; Purna Mukhopadhyay; John A Spertus; Qingjiang Hou; Theresa I Shireman Journal: Kidney Int Date: 2011-12-21 Impact factor: 10.612
Authors: Wanwarat Ananthapanyasut; Sirikarn Napan; Earl H Rudolph; Tasma Harindhanavudhi; Husam Ayash; Kelly E Guglielmi; Edgar V Lerma Journal: Clin J Am Soc Nephrol Date: 2009-12-10 Impact factor: 8.237
Authors: Nancy Krieger; Pamela Waterman; Jarvis T Chen; Mah-Jabeen Soobader; S V Subramanian; Rosa Carson Journal: Am J Public Health Date: 2002-07 Impact factor: 9.308
Authors: Alvaro Alonso; Sunil K Agarwal; Elsayed Z Soliman; Marietta Ambrose; Alanna M Chamberlain; Ronald J Prineas; Aaron R Folsom Journal: Am Heart J Date: 2009-07 Impact factor: 4.749
Authors: Jennifer E Flythe; Sai Liu; Maria E Montez-Rath; Wolfgang C Winkelmayer; Tara I Chang Journal: Nephrol Dial Transplant Date: 2021-11-09 Impact factor: 7.186