| Literature DB >> 31170760 |
Cenker Zeki Koyuncuoglu1, Duygu Yaman1, Gokhan Kasnak1, Korkud Demirel1.
Abstract
OBJECTIVE: Various suture materials and needles are now available for use in the dental surgery. The aim of this study was to determine the preference of suture materials among Turkish dentists by a dental survey.Entities:
Year: 2019 PMID: 31170760 PMCID: PMC6635974 DOI: 10.1055/s-0039-1688732
Source DB: PubMed Journal: Eur J Dent
Fig. 1The survey consists of 15 questions, and the first eight questions are shown.
Periodontal and dental implant operations versus suture preferences (absorbable or nonabsorbable, monofilament or braided multifilament, and diameter of the thread)
| Suture material |
Periodontal flap,
|
Guided tissue regeneration,
|
Frenectomy,
|
Free gingival graft,
|
Connective tissue graft,
|
Dental implant,
|
Guided bone regeneration,
|
|---|---|---|---|---|---|---|---|
| Absorbable | 22 (16.2) | 30 (22.1) | 59 (43.4) | 42 (30.9) | 46 (33.8) | 14 (10.3) | 22 (16.2) |
| Nonabsorbable | 103 (75.7) | 82 (60.3) | 57 (41.8) | 62 (45.6) | 49 (36.0) | 110 (80.9) | 79 (58.1) |
| Both | 1 (0.7) | 2 (1.5) | 4 (3.0) | 6 (4.4) | 10 (7.4) | 6 (4.4) | 5 (3.7) |
| No response | 10 (7.4) | 22 (16.2) | 16 (11.8) | 26 (19.1) | 31 (22.8) | 6 (4.4) | 30 (22.1) |
| Braided | 58 (42.6) | 23 (16.9) | 52 (38.2) | 36 (26.5) | 27 (19.9) | 56 (41.2) | 29 (21.3) |
| Monofilament | 56 (41.2) | 86 (63.2) | 61 (44.9) | 72 (52.9) | 68 (50.0) | 62 (45.6) | 69 (50.7) |
| Both | 11 (8.1) | 5 (3.7) | 5 (3.7) | 1 (0.7) | 9 (6.6) | 9 (6.6) | 10 (7.4) |
| No response | 11 (8.1) | 22 (16.2) | 18 (13.2) | 27 (19.9) | 32 (23.5) | 9 (6.6) | 28 (20.6) |
| 3–0 | 17 (12.5) | 16 (11.8) | 16 (11.8) | 6 (4.4) | 6 (4.4) | 29 (21.3) | 13 (9.6) |
| 4–0 | 31 (22.8) | 25 (18.4) | 44 (32.4) | 15 (11.0) | 10 (7.4) | 34 (25.0) | 26 (19.1) |
| 5–0 | 28 (20.6) | 53 (39.0) | 47 (34.6) | 42 (30.9) | 40 (29.4) | 30 (22.1) | 33 (24.3) |
| 6–0 | 6 (4.4) | 19 (14.0) | 11 (8.0) | 23 (16.9) | 26 (19.1) | 1 (0.7) | 5 (3.7) |
| 3–0 + 4–0 | 12 (8.8) | 0 | 0 | 3 (2.2) | 2 (1.5) | 14 (10.3) | 8 (5.9) |
| 3–0 + 5–0 | 4 (3.0) | 0 | 0 | 1 (0.7) | 0 | 2 (1.5) | 1 (0.7) |
| 4–0 + 5–0 | 12 (8.8) | 1 (0.7) | 1 (0.7) | 9 (6.6) | 4 (2.9) | 11 (8.1) | 10 (7.4) |
| 5–0 + 6–0 | 3 (2.2) | 1 (0.7) | 1 (0.7) | 8 (5.9) | 10 (7.4) | 3 (2.2) | 9 (6.6) |
| 3–0 + 4–0 + 5–0 | 6 (4.4) | 0 | 0 | 0 | 2 (1.5) | 3 (2.2) | 3 (2.2) |
| 4–0 + 5–0 + 6–0 | 5 (3.7) | 0 | 0 | 1 (0.7) | 3 (2.2) | 1 (0.7) | 2 (1.5) |
| Other combinations | 3 (2.2) | 0 | 0 | 0 | 0 | 1 (0.7) | 0 |
| No response | 9 (6.6) | 21 (15.4) | 16 (11.8) | 28 (20.6) | 33 (24.2) | 7 (5.2) | 26 (19.0) |
Periodontal and dental implant operations versus needle characteristics (needle cutting edge and shape)
| Needle |
Periodontal flap,
|
Guided tissue regeneration,
|
Frenectomy,
|
Free gingival graft,
|
Connective tissue graft,
|
Dental implant,
|
Guided bone regeneration,
|
|---|---|---|---|---|---|---|---|
| Circular shaped | 20 (14.7) | 25 (18.4) | 30 (22.1) | 27 (19.9) | 25 (18.4) | 19 (14.0) | 10 (7.4) |
| Reverse cutting | 62 (45.6) | 56 (41.2) | 50 (36.8) | 53 (39.0) | 50 (36.8) | 61 (44.9) | 59 (43.3) |
| Cutting | 33 (24.3) | 34 (25.0) | 30 (22.1) | 21 (15.4) | 24 (17.6) | 40 (29.4) | 30 (22.1) |
| Combinations | 11 (8.1) | 0 | 9 (6.5) | 7 (5.1) | 5 (3.7) | 9 (6.6) | 11 (8.1) |
| No response | 10 (7.4) | 21 (15.4) | 17 (12.5) | 28 (20.6) | 32 (23.5) | 7 (5.2) | 26 (19.1) |
| 1/2 circle | 19 (14.0) | 12 (8.8) | 14 (10.3) | 25 (18.4) | 16 (11.8) | 21 (15.4) | 12 (8.8) |
| 3/8 circle | 99 (72.8) | 90 (66.2) | 90 (66.2) | 88 (64.7) | 80 (58.8) | 97 (71.3) | 88 (64.7) |
| Straight | 2 (1.5) | 3 (2.2) | 2 (1.5) | 3 (2.2) | 3 (2.2) | 3 (2.2) | 2 (1.5) |
| Combinations | 5 (3.7) | 6 (4.4) | 2 (1.5) | 0 | 4 (2.9) | 5 (3.7) | 6 (4.4) |
| No response | 11 (8.1) | 25 (18.4) | 28 (20.0) | 20 (14.7) | 33 (24.3) | 10 (7.4) | 28 (20.6) |