Quantitative ultrasound (QUS) axial transmission method reflects anisotropy in micro-arrangement of apatite crystallites in human long bones: A study with 3-MHz-frequency ultrasound.

Takuya Ishimoto1, Ryoichi Suetoshi2, Dorian Cretin2, Koji Hagihara3, Jun Hashimoto4, Akio Kobayashi5, Takayoshi Nakano6.   

Abstract

Anisotropic arrangement of apatite crystallites, i.e., preferential orientation of the apatite c-axis, is known to be an important bone quality parameter that governs the mechanical properties. However, noninvasive evaluation of apatite orientation has not been achieved to date. The present paper reports the potential of quantitative ultrasound (QUS) for noninvasive evaluation of the degree of apatite orientation in human bone for the first time. A novel QUS instrument for implementation of the axial transmission (AT) method is developed, so as to achieve precise measurement of the speed of sound (SOS) in the cortex (cSOS) of human long bone. The advantages of our QUS instrument are the following: (i) it is equipped with a cortical bone surface-morphology detection system to correct the ultrasound transmission distance, which should be necessary for AT measurement of long bone covered by soft tissue of non-uniform thickness; and (ii) ultrasound with a relatively high frequency of 3 MHz is employed, enabling thickness-independent cSOS measurement even for the thin cortex by preventing guide wave generation. The reliability of the proposed AT measurement system is confirmed through comparison with the well-established direct transmission (DT) method. The cSOS in human long bone is found to exhibit considerable direction-dependent anisotropy; the axial cSOS (3870 ± 66 m/s) is the highest, followed by the tangential (3411 ± 94 m/s) and radial (3320 ± 85 m/s) cSOSs. The degree of apatite orientation exhibits the same order, despite the unchanged bone mineral density. Multiple regression analysis reveals that the cSOS of human long bone strongly reflects the apatite orientation. The cSOS determined by the AT method is positively correlated with that determined by the DT method and sensitively reflects the apatite orientation variation, indicating the validity of the AT instrument developed in this study. Our instrument will be beneficial for noninvasive evaluation of the material integrity of the human long-bone cortex, as determined by apatite c-axis orientation along the axial direction.
Copyright © 2019 The Author(s). Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Anisotropy; Apatite orientation; Bone quality; Leaky surface wave; Speed of sound (SOS)

Year:  2019        PMID: 31170537     DOI: 10.1016/j.bone.2019.05.034

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  3 in total

1.  Signal Processing Techniques Applied to Axial Transmission Ultrasound.

Authors:  Tho N H T Tran; Kailiang Xu; Lawrence H Le; Dean Ta
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

2.  Axial Transmission: Techniques, Devices and Clinical Results.

Authors:  Nicolas Bochud; Pascal Laugier
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 2.622

3.  Defining disease progression in Chinese mainland people: Association between bone mineral density and knee osteoarthritis.

Authors:  Liang Fang; Chenjie Xia; Huihui Xu; Qinwen Ge; Zhenyu Shi; Liya Kong; Peng Zhang; Rui Xu; Zhen Zou; Pinger Wang; Hongting Jin; Peijian Tong
Journal:  J Orthop Translat       Date:  2020-11-06       Impact factor: 5.191

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.