Literature DB >> 31167616

"Targeted Percutaneous Vertebroplasty" Versus Traditional Percutaneous Vertebroplasty for Osteoporotic Vertebral Compression Fracture.

JunChuan Xu1, JiSheng Lin1, Jian Li1, Yong Yang1, Qi Fei1.   

Abstract

Objective. In this randomized, nonblinded, controlled study, the feasibility and precision of "targeted percutaneous vertebroplasty" ("targeted PVP") for osteoporotic vertebral compression fracture (OVCF) was evaluated. Methods. A total of 42 patients, aged 50 to 87 years, with OVCF were randomly divided into 2 groups: A and B. Group A underwent "targeted PVP," and group B underwent traditional PVP with the guidance of C-arm fluoroscopy. Fluoroscopy times for skin puncture points (FTSPP), total radiation doses (TRD), total fluoroscopy times (TFT), and operation time were set as the main evaluation indicators. Results. FTSPP (1.52 ± 0.51 in group A vs 6.62 ± 2.58 in group B, U < .001), TRD (6.26 ± 1.51 in group A vs 11.32 ± 4.21 in group B, P < .001), TFT (16.57 ± 2.79 in group A vs 26.05 ± 6.18 in group B, P < .001), and operation time (20.05 ± 3.38 in group A vs 25.43 ±5.11 in group B, U < .001) were statistically different in the 2 groups. The incidence of cement leakage that occurred in group A (1/21, 4.76%) was significantly less than that in group B (9/21, 42.9%, P < 0.05). Conclusions. "Targeted PVP" may achieve (1) less skin positioning fluoroscopy times, less total fluoroscopy times and dose, shorter operation time, which is more precise than traditional PVP; (2) less incidence of cement leakage; and (3) visualization of the fractured vertebra, which is probably more valuable for the treatment of complicated OVCF patients.

Entities:  

Keywords:  3-dimensional model; Materialise Interactive Medical Image Control System; osteoporotic vertebral compression fracture; percutaneous vertebroplasty

Mesh:

Year:  2019        PMID: 31167616     DOI: 10.1177/1553350619853134

Source DB:  PubMed          Journal:  Surg Innov        ISSN: 1553-3506            Impact factor:   2.058


  1 in total

1.  Clinical Effect of Bone Filling Mesh Container Vertebroplasty in Osteoporotic Compression Fracture.

Authors:  Zhiqian Wang; Guomin Li; Jingming He; Haifeng Huang; Anju Zhao
Journal:  Dis Markers       Date:  2022-08-02       Impact factor: 3.464

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.