Literature DB >> 31167602

Safety of Next-Day Discharge After Transfemoral Transcatheter Aortic Valve Replacement With a Self-Expandable Versus Balloon-Expandable Valve Prosthesis.

Noriaki Moriyama1,2, Antti Vento1, Mika Laine1.   

Abstract

Background The safety of next-day discharge (NDD) after transcatheter aortic valve replacement (TAVR) with a self-expandable valve is unknown. We investigated the safety of NDD after TAVR in patients who received a self-expandable valve or balloon-expandable valve. Methods and Results We retrospectively evaluated consecutive patients who underwent elective minimalist TAVR between January 2017 and July 2018. We investigated the success rates and predictors of NDD after TAVR. Ninety-day and 1-year outcomes in patients managed with NDD after self-expandable ACURATE neo or balloon-expandable SAPIEN 3 replacement were compared. In 315 TAVRs, 249 patients received an ACURATE neo (n=146) or SAPIEN 3 (n=103) valve. There were no differences in baseline characteristics. In the ACURATE neo and SAPIEN 3 groups, NDD was achieved in 60% (n=87) and 55% (n=57) of patients, respectively ( P>0.50). Predictors of NDD included chronic obstructive pulmonary disease (odds ratio, 0.49; 95% CI, 0.25-0.94) and low pre-TAVR hemoglobin (odds ratio, 0.98; 95% CI, 0.96-0.99) but not type of valve (odds ratio, 1.20; 95% CI, 0.71-1.98 for ACURATE neo). After excluding non-NDD cases, there were no significant differences in 90-day mortality (0% versus 0%; P>0.90) or new pacemaker implantation (1% versus 0%; P>0.40) between ACURATE neo and SAPIEN3, respectively. No significant difference in 1-year mortality between ACURATE neo and SAPIEN 3 groups after NDD (8% versus 10%; log-rank, P>0.80) was observed. Conclusions The safety of NDD using ACURATE neo was similar that using SAPIEN 3, with comparable 90-day and 1-year outcomes.

Entities:  

Keywords:  discharge; safety; transcatheter aortic valve replacement

Year:  2019        PMID: 31167602     DOI: 10.1161/CIRCINTERVENTIONS.118.007756

Source DB:  PubMed          Journal:  Circ Cardiovasc Interv        ISSN: 1941-7640            Impact factor:   6.546


  8 in total

Review 1.  Update on Minimalist TAVR Care Pathways: Approaches to Care in 2022.

Authors:  Mariem A Sawan; Avery E Calhoun; Kendra J Grubb; Chandan M Devireddy
Journal:  Curr Cardiol Rep       Date:  2022-06-29       Impact factor: 3.955

2.  Incidence and Predictors of Access Site Vascular Complications Following Ultrasound-Guided MANTA Closure Deployment.

Authors:  Hirokazu Miyashita; Noriaki Moriyama; Mika Laine
Journal:  J Endovasc Ther       Date:  2021-12-01       Impact factor: 3.089

3.  Transcatheter Aortic Valve Replacement with Self-Expandable ACURATE neo as Compared to Balloon-Expandable SAPIEN 3 in Patients with Severe Aortic Stenosis: Meta-Analysis of Randomized and Propensity-Matched Studies.

Authors:  Mirosław Gozdek; Kamil Zieliński; Michał Pasierski; Matteo Matteucci; Dario Fina; Federica Jiritano; Paolo Meani; Giuseppe Maria Raffa; Pietro Giorgio Malvindi; Michele Pilato; Domenico Paparella; Artur Słomka; Jacek Kubica; Dariusz Jagielak; Roberto Lorusso; Piotr Suwalski; Mariusz Kowalewski
Journal:  J Clin Med       Date:  2020-02-01       Impact factor: 4.241

Review 4.  An Update on New Generation Transcatheter Aortic Valves and Delivery Systems.

Authors:  Gloria Santangelo; Alfonso Ielasi; Mariano Pellicano; Azeem Latib; Maurizio Tespili; Francesco Donatelli
Journal:  J Clin Med       Date:  2022-01-19       Impact factor: 4.241

5.  Wearable Smartwatch Facilitated Remote Health Management for Patients Undergoing Transcatheter Aortic Valve Replacement.

Authors:  Xianbao Liu; Jiaqi Fan; Yuchao Guo; Hanyi Dai; Jianguo Xu; Lihan Wang; Po Hu; Xinping Lin; Cheng Li; Dao Zhou; Huajun Li; Jian'an Wang
Journal:  J Am Heart Assoc       Date:  2022-03-29       Impact factor: 5.501

6.  Same-Day Discharge After Transcatheter Aortic Valve Implantation: Insights from the Nationwide Readmission Database 2015 to 2019.

Authors:  Salman Zahid; Devesh Rai; Mian Tanveer Ud Din; Muhammad Zia Khan; Waqas Ullah; Muhammad Usman Khan; Samarthkumar Thakkar; Ahmed Hussein; Bipul Baibhav; Mohan Rao; Farhad Abtahian; Deepak L Bhatt; Jeremiah P Depta
Journal:  J Am Heart Assoc       Date:  2022-05-27       Impact factor: 6.106

Review 7.  ACURATE neo: How Is This TAVR Valve Doing to Fit into an Increasingly Crowded Field?

Authors:  Taishi Okuno; Jonas Lanz; Thomas Pilgrim
Journal:  Curr Cardiol Rep       Date:  2020-08-08       Impact factor: 2.931

8.  Temporal Changes in Mortality After Transcatheter and Surgical Aortic Valve Replacement: Retrospective Analysis of US Medicare Patients (2012-2019).

Authors:  Sandra B Lauck; Suzanne J Baron; William Irish; Britt Borregaard; Kimberly A Moore; Candace L Gunnarsson; Seth Clancy; David A Wood; Vinod H Thourani; John G Webb; Harindra C Wijeysundera
Journal:  J Am Heart Assoc       Date:  2021-09-28       Impact factor: 5.501

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.