Feasibility of fast non local means filter in pediatric chest x-ray for increasing of pulmonary nodule detectability with 3D printed lung nodule phantom.

Jina Shim1, Myonggeun Yoon, Youngjin Lee.   

Abstract

General x-ray images have a lower probability of nodule detection than other modalities. Especially in children, the probability of nodule detection can likely drop due to poor image quality from using low radiation dose. To demonstrate the effectiveness of fast non-local means (FNLM) filter to increase the probability of nodule detection in pediatric chest x-ray images and reduce radiation dose while maintaining image quality. Quantitative assessment of normalised noise power spectrum (NNPS), coefficient of variation (COV) and contrast to noise ratio (CNR) were performed after applying four filters (median, Wiener, total variation and FNLM) on a 1-year-old child phantom. A 3D-printed patient nodule phantom was inserted into the phantom. Assessment was performed on AP and LAT view images acquired with the tube voltage reduced to 38 and 27%, and tube current reduced to 84 and 61%, respectively. The results showed the lowest NNPS and COV values and the highest CNR value when the FNLM filter applied. Moreover, the AP view results showed 37% decrease in COV and 30% increase in CNR in images with the FNLM filter applied (images exposed with the tube voltage and current reduced to 29% and 50%, respectively). The LAT view results showed 5% decrease in COV and 36% increase in CNR in images with the FNLM filter applied (images exposed with the tube current reduced by 27%). By applying the FNLM filter, the probability of nodule detection could be increased by denoising and contrast enhancement. Moreover, using the FNLM filter could reduce cancer risk in pediatric patients by reducing radiation dose about 30% to 44%.

Entities:  

Year:  2019        PMID: 31167171     DOI: 10.1088/1361-6498/ab2755

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  2 in total

1.  Effectiveness of Non-Local Means Algorithm with an Industrial 3 MeV LINAC High-Energy X-Ray System for Non-Destructive Testing.

Authors:  Kyuseok Kim; Jaegu Choi; Youngjin Lee
Journal:  Sensors (Basel)       Date:  2020-05-05       Impact factor: 3.576

2.  Towards to Optimal Wavelet Denoising Scheme-A Novel Spatial and Volumetric Mapping of Wavelet-Based Biomedical Data Smoothing.

Authors:  Ladislav Stanke; Jan Kubicek; Dominik Vilimek; Marek Penhaker; Martin Cerny; Martin Augustynek; Nikola Slaninova; Muhammad Usman Akram
Journal:  Sensors (Basel)       Date:  2020-09-16       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.