| Literature DB >> 31163775 |
Arunita Kar, Meisam Bahadori, Songbin Gong, Lynford L Goddard.
Abstract
We present the design, modeling, fabrication, and characterization of grating coupler devices for z-cut lithium niobate near 1550 nm. We first experimentally measure the sensitivity of the insertion loss of a conventional grating coupler to translational misalignment through a three-factor full factorial design of experiment. Next, we design grating couplers that are significantly less sensitive to misalignment. The fabricated devices experienced less than 7 dB of excess insertion loss for combined misalignments of up to ± 5 μm in plane and up to -2 μm or + 10 μm out of plane.Entities:
Year: 2019 PMID: 31163775 DOI: 10.1364/OE.27.015856