Literature DB >> 31163511

Metal About the Hip and Artifact Reduction Techniques: From Basic Concepts to Advanced Imaging.

Iman Khodarahmi1, Amanda Isaac2,3, Elliot K Fishman4, Danoob Dalili2,3,4, Jan Fritz4.   

Abstract

Promising outcomes of hip replacement interventions in this era of aging populations have led to higher demands for hip arthroplasty procedures. These require effective methods and techniques for the detection of postoperative outcomes and complications. Based on the presence or absence of radiographic findings, magnetic resonance imaging (MRI) and computed tomography (CT) may be required to detect and further characterize different causes of failing implants. Yet metal-related artifacts degrade image quality and pose significant challenges for adequate image quality. To mitigate such artifacts in MRI, a set of techniques, collectively known as metal artifact reduction sequence (MARS) MRI, were developed that optimize the framework of the conventional pulse sequences and exploit novel multispectral and multispatial imaging methods such as Slice Encoding for Metal Artifact Correction (SEMAC) and Multi-Acquisition Variable-Resonance Image Combination (MAVRIC). Metal-induced artifacts on CT can be effectively reduced with virtual monochromatic reconstruction of dual-energy CT data sets, metal artifact reduction reconstruction algorithms, and postprocessing image visualization techniques. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31163511     DOI: 10.1055/s-0039-1687898

Source DB:  PubMed          Journal:  Semin Musculoskelet Radiol        ISSN: 1089-7860            Impact factor:   1.777


  6 in total

Review 1.  Imaging following surgery for primary appendicular bone tumours.

Authors:  Imran Khan; Craig Gerrand; Asif Saifuddin
Journal:  Skeletal Radiol       Date:  2021-01-22       Impact factor: 2.199

Review 2.  MRI-guided sacroiliac joint injections in children and adults: current practice and future developments.

Authors:  Danoob Dalili; Amanda Isaac; Jan Fritz
Journal:  Skeletal Radiol       Date:  2022-08-25       Impact factor: 2.128

3.  Metal Artefact Reduction Sequences (MARS) in Magnetic Resonance Imaging (MRI) after Total Hip Arthroplasty (THA) : A non-invasive approach for preoperative differentiation between periprosthetic joint infection (PJI) and aseptic complications?

Authors:  André Busch; Marcus Jäger; Sascha Beck; Alexander Wegner; Erik Portegys; Dennis Wassenaar; Jens Theysohn; Johannes Haubold
Journal:  BMC Musculoskelet Disord       Date:  2022-06-28       Impact factor: 2.562

Review 4.  [Metallic Artifacts on MR Imaging and Methods for Their Reduction].

Authors:  Hye Jung Choo; Sun Joo Lee; Young Han Lee
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2020-01-31

5.  Metal artifacts reduction in computed tomography: A phantom study to compare the effectiveness of metal artifact reduction algorithm, model-based iterative reconstruction, and virtual monochromatic imaging.

Authors:  Takuya Ishikawa; Shigeru Suzuki; Shingo Harashima; Rika Fukui; Masafumi Kaiume; Yoshiaki Katada
Journal:  Medicine (Baltimore)       Date:  2020-12-11       Impact factor: 1.817

6.  AI-based detection and classification of distal radius fractures using low-effort data labeling: evaluation of applicability and effect of training set size.

Authors:  Patrick Tobler; Joshy Cyriac; Balazs K Kovacs; Verena Hofmann; Raphael Sexauer; Fabiano Paciolla; Bram Stieltjes; Felix Amsler; Anna Hirschmann
Journal:  Eur Radiol       Date:  2021-03-19       Impact factor: 5.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.