Literature DB >> 31162850

New versatile dual-support pediatric heart pump.

Carson Fox1, Harutyun Sarkisyan1, Randy Stevens2, Francisco Arabia3, Wade Fischer4, Joseph Rossano5, Amy Throckmorton1.   

Abstract

Mechanical circulatory support (MCS) devices for pediatric patients continue to lag in development behind those for adults. There is no heart pump with the design innovation to support dysfunctional states of heart failure and the anatomic heterogeneity of cardiac defects in pediatric patients. To address this unmet need, we are developing a versatile MCS technology with 2 separate blood pumps under 1 housing, whereby a centrifugal pump rotates around an axial pump. In this study, we advanced the design with a new inducer for the axial pump component and flat inlet volute for the centrifugal pump component. We conducted computational modeling of the design iterations, built prototypes, and tested their performance. The axial pump component was able to generate pressure rises of 1-112 mm Hg for 2-5 L/min at 10 000-14 000 RPM, and the centrifugal pump component produced pressure rises of 1-184 mm Hg for 2-5 L/min at 1750-3000 RPM. Shear stresses and blood damage estimations were less than  490 Pa and 0.5%, respectively. Axial and radial forces were also estimated to be less than 5 N for the axially and radially centered impellers. Data sets were repeatable, and data trends followed theoretical expectations. The new designs for the axial and centrifugal pumps enabled us to reduce the height of the pump while maintaining performance expectations. These findings support the continued development of this new medical device for pediatric patients.
© 2019 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  blood pump; mechanical circulatory assistance; pediatric circulatory support; rotary blood pump; total artificial heart; ventricular assist device

Mesh:

Year:  2019        PMID: 31162850     DOI: 10.1111/aor.13507

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Microscale impeller pump for recirculating flow in organs-on-chip and microreactors.

Authors:  Sophie R Cook; Hannah B Musgrove; Amy L Throckmorton; Rebecca R Pompano
Journal:  Lab Chip       Date:  2022-02-01       Impact factor: 6.799

Review 2.  Technology landscape of pediatric mechanical circulatory support devices: A systematic review 2010-2021.

Authors:  Thomas Palazzolo; Matthew Hirschhorn; Ellen Garven; Steven Day; Randy M Stevens; Joseph Rossano; Vakhtang Tchantchaleishvili; Amy L Throckmorton
Journal:  Artif Organs       Date:  2022-04-14       Impact factor: 2.663

3.  Development of the Centrifugal Blood Pump for a Hybrid Continuous Flow Pediatric Total Artificial Heart: Model, Make, Measure.

Authors:  Carson S Fox; Thomas Palazzolo; Matthew Hirschhorn; Randy M Stevens; Joseph Rossano; Steven W Day; Vakhtang Tchantchaleishvili; Amy L Throckmorton
Journal:  Front Cardiovasc Med       Date:  2022-08-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.