Jamie K Harrington1,2, Diego Porras1,2, Nicola Maschietto1,2, Gerald R Marx1,2.
Abstract
Transcatheter closure of mitral paravalvular leaks has become an accepted alternative to surgical repair, especially in patients at high risk for reoperation. Device placement using three-dimensional (3D) transesophageal echocardiography (TEE) guidance allows en-face views of the valve and provides detailed information for device sizing and placement. We present a case demonstrating hybrid transapical transcatheter 3D TEE-guided closure of two mitral paravalvular leaks. We demonstrate real time 3D TEE guidance for device sizing and placement, and early real time recognition of mechanical mitral valve leaflet impairment during device deployment.Entities:
Keywords: paravalvular leak; three-dimensional transesophageal echocardiography; transcatheter