Literature DB >> 31161678

Impact of number of registration points on the positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan by surface scan registration: An in vitro study.

Faris Z Jamjoom1, Burak Yilmaz2, William M Johnston2.   

Abstract

OBJECTIVES: To evaluate the accuracy of a prosthetic treatment plan incorporation into a cone beam computed tomography (CBCT) scan using point-based registration with three registration points selected and to evaluate the impact of number of registration points on prosthetic plan accuracy.
MATERIAL AND METHODS: A CBCT scan of a completely dentate master model with removable teeth was exposed after removing the mandibular left first premolar, second premolar, and first molar. A digital scan of the master model with all teeth present was made by scanning a stone replica using a laboratory scanner. The digital model was registered onto the three-dimensional (3D) volume rendering of the CBCT scan using implant planning software. The point-based registration was repeated using three, four, five, six, seven, eight, nine, and 10 reference points. Metrology software was used to measure the 3D deviation of the registered models for each reference point group on standard tessellation language (STL) files obtained from the CBCT scans. An STL file of the master model with all teeth present obtained from another CBCT scan was used as reference.
RESULTS: Using three registration points, the registered prosthetic plan had a mean absolute deviation of 17.63 µm from the reference. Increasing the number of registration points failed to demonstrate statistically significant effects on the deviation (p > 0.05).
CONCLUSIONS: For this clinical scenario, three registration points provided adequate accuracy for prosthetic plan incorporation into CBCT scans. Increasing the number of registration points had no significant impact on the prosthetic plan accuracy in this study.
© 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Keywords:  accuracy; computer-assisted implant planning; cone beam computer tomography; image registration; point-based registration

Mesh:

Year:  2019        PMID: 31161678     DOI: 10.1111/clr.13490

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

1.  Evaluation of different registration methods and dental restorations on the registration duration and accuracy of cone beam computed tomography data and intraoral scans: a retrospective clinical study.

Authors:  Xing-Yu Piao; Ji-Man Park; Hannah Kim; Youngjun Kim; June-Sung Shim
Journal:  Clin Oral Investig       Date:  2022-05-10       Impact factor: 3.606

2.  Impact of Matching Point Selections on Image Registration Accuracy between Optical Scan and Computed Tomography.

Authors:  Hai Yen Mai; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2020-08-04       Impact factor: 3.411

  2 in total