Literature DB >> 31160126

Two-dimensional spatial error distribution of key tensiomyographic parameters.

Boštjan Šimunič1.   

Abstract

Tensiomyography detects the contraction time (Tc) and amplitude (Dm) of muscle belly thickening during maximal isometric twitch contraction. The assessment of both parameters is highly reliable; however, it seems that their calculation depends on the measurement point. The aim of the study was to determine spatial relative error distribution of Tc and/or Dm within a two-dimensional array of 27 (3 × 9) measurement points in comparison to the reference point (RP) in 12 male participants (22.5 ± 3.1 years). The RPs were determined as follows: in the biceps brachii (BB) at 50% of the humerus length; in the erector spinae (ES) at the height of the iliac crest; in the vastus lateralis (VL), vastus medalis (VM), and rectus femoris (RF) at 30%, 20%, and 50% of femur length above the patella, respectively. The surface area under the 3% relative error in Dm (BB: 4.0; VL: 3.8; VM; 8.2; RF: 6.2; ES: 2.4 cm2) was lower than in Tc (BB: 6.9; VL: 3.8; VM; 4.6; RF: 9.5; ES: 3.7 cm2), yielding merged values (BB: 3.9; VL: 3.7; VM; 4.8; RF: 5.1; ES: 2.4 cm2). Dm show twice as steep relative error rate when moving away from the RP in comparison to Tc, which seems to be less sensitive to spatial sensor positioning.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Contraction time; MHC; Maximal displacement; Skeletal muscle; TMG

Year:  2019        PMID: 31160126     DOI: 10.1016/j.jbiomech.2019.05.035

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  5 in total

1.  Lower-Limb Muscle Contractile Properties, Explosive Power and the Subjective Response of Elite Soccer Players to the COVID-19 Lockdown.

Authors:  Armin H Paravlic; Bostjan Simunic; Sasa Pisot; Matej Kleva; Kaja Teraz; Matjaz Vogrin; Uros Marusic; Rado Pisot
Journal:  Int J Environ Res Public Health       Date:  2022-01-01       Impact factor: 3.390

2.  The Association between Tensiomyography and Elastography Stiffness Measurements in Lower Limb Skeletal Muscles.

Authors:  Abdulrahman M Alfuraih; Ahmed Alhowimel; Sara Alghanim; Yaaqoub Khayat; Abdulaziz Aljamaan; Hana I Alsobayel
Journal:  Sensors (Basel)       Date:  2022-02-05       Impact factor: 3.576

3.  Decomposition of tensiomyogram and comparison with torque twitch responses after post-activation potentiation.

Authors:  Ensar Abazović; Armin Paravlić; Damir Zubac; Erol Kovačević; Boštjan Šimunič
Journal:  J Musculoskelet Neuronal Interact       Date:  2022-09-01       Impact factor: 1.864

4.  Objective Assessment of Regional Stiffness in Vastus Lateralis with Different Measurement Methods: A Reliability Study.

Authors:  Alfredo Bravo-Sánchez; Pablo Abián; Jorge Sánchez-Infante; Paula Esteban-Gacía; Fernando Jiménez; Javier Abián-Vicén
Journal:  Sensors (Basel)       Date:  2021-05-06       Impact factor: 3.576

5.  Correlation between timed up and go test and skeletal muscle tensiomyography in female nursing home residents.

Authors:  Ester Fabiani; Mladen Herc; Boštjan Šimunič; Bianca Brix; Kerstin Löffler; Lisa Weidinger; Andreas Ziegl; Peter Kastner; Alen Kapel; Nandu Goswami
Journal:  J Musculoskelet Neuronal Interact       Date:  2021-06-01       Impact factor: 2.041

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.