Literature DB >> 31150985

Flexible electrochemical glucose biosensor based on GOx/gold/MoS2/gold nanofilm on the polymer electrode.

Jinho Yoon1, Sang Nam Lee2, Min Kyu Shin1, Hyun-Woong Kim1, Hye Kyu Choi1, Taek Lee3, Jeong-Woo Choi4.   

Abstract

The need for flexible biosensors has increased because of their potential applications for point-of-care diagnosis and wearable biosensors. However, flexible biosensors have low sensitivity due to the flexibility of the electrode, and their fabrication involves complex processes. To overcome these limitations, a flexible electrochemical enzyme biosensor was developed in this study by immobilizing an enzyme on the flexible polymer electrode modified with a gold/MoS2/gold nanofilm. The fabrication process involved sputter deposition of gold, spin coating of MoS2, and sputter deposition of gold on the flexible polymer electrode (commercially available Kapton® polyimide film). The flexible glucose biosensor was made by immobilization of glucose oxidase on a flexible electrode by using a chemical linker. The detection limit for glucose was estimated to be 10 nM, which indicates more sensitivity as compared with a previously reported flexible glucose sensor. This sensitivity is due to the facilitation of electron transfer by MoS2. The flexure extension of this biosensor was estimated at 3.48 mm, which is much higher than that of the rigid sensor using a gold-coated silicon electrode (0.09 mm), according to measurements with a micro-fatigue tester. The proposed flexible biosensor composed of the enzyme/gold/MoS2/gold nanofilm on the polymer electrode can be used as a flexible sensing platform for developing wearable biosensing systems because of its high sensitivity, high flexibility, and simple fabrication process.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biosensor; Flexibility; Glucose; MoS(2) nanoparticle; Spin coating; Sputter deposition of gold

Year:  2019        PMID: 31150985     DOI: 10.1016/j.bios.2019.111343

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  14 in total

Review 1.  Recent Developments and Future Perspective on Electrochemical Glucose Sensors Based on 2D Materials.

Authors:  Sithara Radhakrishnan; Seetha Lakshmy; Shilpa Santhosh; Nandakumar Kalarikkal; Brahmananda Chakraborty; Chandra Sekhar Rout
Journal:  Biosensors (Basel)       Date:  2022-06-28

Review 2.  Prospects of Biosensors Based on Functionalized and Nanostructured Solitary Materials: Detection of Viral Infections and Other Risks.

Authors:  Sanjeev Kumar; Ritika Sharma; Akanksha Gupta; Prashant Singh; Susheel Kalia; Pankaj Thakur; Vinod Kumar
Journal:  ACS Omega       Date:  2022-06-22

Review 3.  Highly Sensitive Biosensors Based on Biomolecules and Functional Nanomaterials Depending on the Types of Nanomaterials: A Perspective Review.

Authors:  Jinho Yoon; Minkyu Shin; Taek Lee; Jeong-Woo Choi
Journal:  Materials (Basel)       Date:  2020-01-09       Impact factor: 3.623

4.  Reusable, Non-Invasive, and Ultrafast Radio Frequency Biosensor Based on Optimized Integrated Passive Device Fabrication Process for Quantitative Detection of Glucose Levels.

Authors:  Yang Li; Zhao Yao; Wenjing Yue; Chunwei Zhang; Song Gao; Cong Wang
Journal:  Sensors (Basel)       Date:  2020-03-11       Impact factor: 3.576

Review 5.  Noble Metal Nanomaterial-Based Biosensors for Electrochemical and Optical Detection of Viruses Causing Respiratory Illnesses.

Authors:  Hye Kyu Choi; Myeong-Jun Lee; Sang Nam Lee; Tae-Hyung Kim; Byung-Keun Oh
Journal:  Front Chem       Date:  2021-05-13       Impact factor: 5.221

Review 6.  Recent Progress in Nanobiosensors for Precise Detection of Blood Glucose Level.

Authors:  Haniye Khosravi Ardakani; Mitra Gerami; Mostafa Chashmpoosh; Navid Omidifar; Ahmad Gholami
Journal:  Biochem Res Int       Date:  2022-01-17

Review 7.  Two-Dimensional Nanostructures for Electrochemical Biosensor.

Authors:  Reem Khan; Antonio Radoi; Sidra Rashid; Akhtar Hayat; Alina Vasilescu; Silvana Andreescu
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

Review 8.  Flexible and wearable electrochemical biosensors based on two-dimensional materials: Recent developments.

Authors:  Minu Mathew; Sithara Radhakrishnan; Antara Vaidyanathan; Brahmananda Chakraborty; Chandra Sekhar Rout
Journal:  Anal Bioanal Chem       Date:  2020-10-23       Impact factor: 4.142

9.  Biomolecules and Electrochemical Tools in Chronic Non-Communicable Disease Surveillance: A Systematic Review.

Authors:  Ana Lúcia Morais; Patrícia Rijo; María Belén Batanero Hernán; Marisa Nicolai
Journal:  Biosensors (Basel)       Date:  2020-09-10

Review 10.  A Critical Review of Electrochemical Glucose Sensing: Evolution of Biosensor Platforms Based on Advanced Nanosystems.

Authors:  Vuslat B Juska; Martyn E Pemble
Journal:  Sensors (Basel)       Date:  2020-10-23       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.