Literature DB >> 31150572

Mechanism of and factors associated with the loosening of the implant abutment screw: A review.

Yiqing Huang1,2, Jiawei Wang1.   

Abstract

OBJECTIVE: While the loosening of the abutment screw is one of the most common complications in implant-supported restorations, there is a lack of comprehensive literatures for mechanism of and factors associated with the loosening of the implant abutment screw. The review was to summarize the mechanism of and factors associated with the loosening of the implant abutment screw. OVERVIEW: A total of 99 relevant articles were included in the literature review. The mechanism of the abutment screw loosening was explained. The factors contributed to abutment screw loosening were divided into five aspects and then expounded respectively.
CONCLUSIONS: The internal connection and abutments with anti-rotational and conical designs have better resistance to screw loosening. Cantilevers increase the risk of screw loosening. The effect of surface treatment of the abutment screw is unsure. Clinicians need to tighten the abutment screw to the recommended torque while avoiding repeated tightening and loosening, and increase the frequency of follow-ups to retighten the loosened screws in time. CLINICAL SIGNIFICANCE: While the loosening of the abutment screw is one of the most common complications in implant-supported restorations, there is a lack of comprehensive literatures for mechanism of and factors associated with the loosening of the implant abutment screw. The review was to summarize the mechanism of and factors associated with the loosening of the implant abutment screw, so that clinicians may make better choices in clinical practice.
© 2019 Wiley Periodicals, Inc.

Keywords:  abutment screw; implant; mechanical complication; screw loosening

Year:  2019        PMID: 31150572     DOI: 10.1111/jerd.12494

Source DB:  PubMed          Journal:  J Esthet Restor Dent        ISSN: 1496-4155            Impact factor:   2.843


  8 in total

1.  A comparative biomechanical study of original and compatible titanium bases: evaluation of screw loosening and 3D-crown displacement following cyclic loading analysis.

Authors:  Rimantas Ožiūnas; Jurgina Sakalauskienė; Darius Jegelevičius; Gintaras Janužis
Journal:  J Adv Prosthodont       Date:  2022-04-27       Impact factor: 1.989

2.  Hybrid-abutment-restoration: effect of material type on torque maintenance and fracture resistance after thermal aging.

Authors:  Walid Al-Zordk; Ahmed Elmisery; Mohamed Ghazy
Journal:  Int J Implant Dent       Date:  2020-06-24

3.  Antibacterial and Antioxidant Effects of Magnesium Alloy on Titanium Dental Implants.

Authors:  Yang Bai; Lin Wang; Lisheng Zhao; E Lingling; Shuo Yang; Shunyi Jia; Ning Wen
Journal:  Comput Math Methods Med       Date:  2022-01-06       Impact factor: 2.238

4.  The effect of the digital manufacturing technique of cantilevered implant-supported frameworks on abutment screw preload.

Authors:  Shahad Mohammmed Altuwaijri; Hanan Nejer Alotaibi; Talal Mughaileth Alnassar
Journal:  J Adv Prosthodont       Date:  2022-02-25       Impact factor: 1.904

5.  Comparison of stresses in monoblock tilted implants and conventional angled multiunit abutment-implant connection systems in the all-on-four procedure.

Authors:  Özge Özdal Zincir; Ateş Parlar
Journal:  BMC Oral Health       Date:  2021-12-16       Impact factor: 2.757

6.  Titanium Base Abutments in Implant Prosthodontics: A Literature Review.

Authors:  Ahmad M Al-Thobity
Journal:  Eur J Dent       Date:  2021-11-18

7.  Passant Connection Screw of Dental Implants: An In Vitro SEM Preliminary Study.

Authors:  Gabriele Cervino; Antonino Germanà; Luca Fiorillo; Cesare D'Amico; Francesco Abbate; Marco Cicciù
Journal:  Biomed Res Int       Date:  2022-04-21       Impact factor: 3.246

8.  Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading.

Authors:  Behnaz Ebadian; Amirhossein Fathi; Saba Khodadad
Journal:  Int J Dent       Date:  2021-07-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.